期刊文献+

舞钢大型电渣炉气雾冷却工艺开发与应用 被引量:3

Development and application of Wugang large electroslag furnace aerosol cooling technology
原文传递
导出
摘要 为提高电渣炉钢锭的内部质量,降低生产成本和改善生产环境,对电渣炉的二次冷却装置及其生产工艺进行了优化。新的气雾冷却装置舞钢2号、3号电渣炉应用后,取得了明显效果:生产现场噪音大幅减轻;电渣钢锭质量明显上升,其探伤合格率由原来的94.83%上升至99.76%;压缩空气成本与原风冷工艺相比,降低了260元/t,经济效益显著。 In order to improve the internal quality of electroslag furnace ingot, reduce the production cost and improve the production environment, the secondary cooling equipment of electroslag furnace and its manufacturing technique had been optimized. The new mist cooling equipment applied in No. 2 and No. 3 electroslag furnace of Wugang Iron and Steel Company, the results showed that the noise of workshop greatly reduced, the qualification rate of electroslag furnace ingot during flaw detection increased from 94.83 % to 99.76 % ,and the compressed air cost reduced 260 yuan/t.
作者 陶林 曹季林 郭宏磊 赵向政 TAO lin;CAO Jilin;GUO Honglei;ZHAO Xiangzheng(Henan Industrial School, Zhengzhou 450002, China;First Steelworks of Wuyang Iron and Steel Company, Wugang 462500, China)
出处 《炼钢》 CAS 北大核心 2018年第3期73-76,共4页 Steelmaking
关键词 电渣炉 气雾冷却 传热 探伤 electroslag furnace mist cooling heat transfer flaw detection
  • 相关文献

参考文献6

二级参考文献16

共引文献55

同被引文献15

引证文献3

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部