摘要 目的观察咳嗽变异性哮喘患者呼出气一氧化氮(FeNO)测定的综合护理干预效果。方法行FeNO测定初诊为咳嗽变异性哮喘患者60例,按照干预方法的不同分为观察组和对照组,每组30例。两组均给予常规干预;观察组在此基础上给予心理、行为等综合护理干预。比较两组FeNO测定成功率和患者满意度,记录测定过程中的不良反应发生情况。结果观察组FeNO测定成功率高于对照组(90.0%vs.73.3%)(P<0.05);观察组测定过程中咳嗽、气喘、心慌、憋气等不良反应的发生率低于对照组(53.3%vs.83.3%)(P<0.05)。观察组患者满意度高于对照组(93.3%vs.86.7%)(P<0.05)。结论综合护理干预可以提高FeNO测定的成功率,减少FeNO测定过程中的不良反应。 Objective To observe the effect of comprehensive nursing intervention in exhaled nitric oxide measurement in the patients with cough-variant asthma.Methods Sixty patients with cough-variant asthma undergoing exhaled nitric oxide measurement were equally assigned into two groups.The patients in group C were given conventional intervention during examination and those in group A were given additional comprehensive intervention including psychology and behavior.The success rate of the exhaled nitric oxide measurement and the degree of satisfaction of patients to the test were compared.The test-related adverse responses were recorded.Results The incidence of success rate of the exhaled nitric oxide measurement was higher in group A than that in group C(90.0% vs.73.3%)(P〈0.05).The incidence of test-related adverse responses such as cough,be short of breath,palpitation and suffocation feeling was lower in group A than that in group C(53.3%vs.83.3%)(P〈0.05).The degree of satisfaction of patients to the test was higher in group A than that in group C(93.3% vs.86.7%)(P〈0.05).Conclusion Comprehensive nursing intervention can elevate the success rate of the exhaled nitric oxide measurement and reduce the incidence of testrelated adverse responses.
作者 孙晓凤 袁阿珍 高小燕 SUN Xiaofeng;YUAN Azhen;GAO Xiaoyan(Department of Respiratory Medicine, People's Hospital of Taizhou , Taizhou 225300, CHIN)
出处 《江苏医药》 CAS 2018年第5期575-577,共3页 Jiangsu Medical Journal
关键词 咳嗽变异性哮喘 呼出气一氧化氮测定 综合护理干预 Cough-variant asthma Exhaled nitric oxide measurement Comprehensive nursing intervention
  • 相关文献

参考文献2

二级参考文献14

  • 1姚慧娟,张悦鸣,李志奎.呼出气一氧化氮检测诊断支气管哮喘[J].中华哮喘杂志(电子版),2013,7(3):10-14. 被引量:6
  • 2马煜,刘传合,黄永坚.呼出气体中的一氧化氮检测与哮喘[J].中华儿科杂志,2005,43(6):421-422. 被引量:19
  • 3武晓兰,唐伟,王聪慧,等.咳嗽变异性哮喘患者Eotaxin的表达及其与肺功能的关系.使用医学杂志[J].2013,29(2):199-201.
  • 4Bateman ED,Hurd SS,Barne PJ,et al,Global strategy forasthma management and prevention:GINA executive summary[J].Eur Respir J,2008,31(1):143-178.
  • 5Dweik R A,Boggs P B,Erzurum S C,et al.An Official ATS clinical practice guideline:interpretation of exhaled nitric oxide levels (FENO) for clinical applications[J].Am J Respir Crit Care Med,2011(184):602-615.
  • 6Majid H,Kao C.Utility of exhaled nitric oxide in the diagnosis and management of asthma[J].Curr 0pin Pulm Med,2010,6 (1):42-47.
  • 7Migneauh A,Sauvageau S.Chronically elevated endothelin levels reduce pulmonary vascular reactivity to nitric oxide[J].Am J Respir Crit Care Med,2005,171(5):506-513.
  • 8Zietkowski Z,Bodzenta.Lukaszyk A,Tomasiak MM,et al.Comparison of exhaled nitric oxide measurement with conventional tests in steroid-native asthma patients[J].J Investig Allergol Clinlmmunol,2006,16:239-246.