摘要 徐州地铁彭城广场站为1号线、2号线的换乘站,双线共用站厅,呈"L"型双向换乘,为地下4层站(局部5层)。地下1层(含地下1层夹层)为大型商业开发,地下2~4层为车站站厅层、站台层。室外可用的市政管道只有一路。从单水源消防供水方案出发,结合消防水源、供水设施、给水形式、室外消火栓设置等情况,设计出4种地铁地下车站消防方案,对4种消防方案的优缺点和适用范围进行了分析,结合本站带大型商业开发的特点,给出了相应的推荐方案。 Xuzhou Metro Pengcheng Plaza Station is a transfer station on line 1 and line 2.The two lane shared station hall is a " L" two-way transfer,which is the 4 tier underground station(5 stories).The underground 1 storey(including underground 1 storey interlayer)is large commercial development,and the underground 2~4 level is the station hall and platform level.There are only one road available outdoor municipal pipeline for single route water supply.From the fire water supply scheme of single source,combined with fire water source,water supply facilities,water supply form and outdoor fire hydrant setting,4 kinds of subway station fire protection schemes were designed,and the advantages and disadvantages and applicable scope of the 4 fire protection schemes were analyzed.With the characteristics of large-scale commercial development,the corresponding recommendation scheme was given.
作者 周金忠 倪吉栋 范太兴 张忠品 杜金海 Zhou Jinzhong;Ni Jidong;Fan Taixing;Zhang Zhongpin;Du Jinhai(China Railway Liuyuan Group Co. , Ltd. , Tianjin 300308, Chin)
出处 《给水排水》 CSCD 北大核心 2018年第6期73-80,共8页 Water & Wastewater Engineering
关键词 地铁地下车站 商业开发 单路供水 给水形式 出入口室外消火栓 Underground subway station Commercial development Single way water supply Water supply form Outlet and outdoor hydrant
  • 相关文献

参考文献2

二级参考文献4

共引文献11

同被引文献27

引证文献5

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部