期刊文献+

A Label-free Fluorescent Aptasensor for Turn-on Monitoring Ochratoxin A Based on AIE-active Probe and Graphene Oxide 被引量:6

A Label-free Fluorescent Aptasensor for Turn-on Monitoring Ochratoxin A Based on AIE-active Probe and Graphene Oxide
原文传递
导出
摘要 A label-free fluorescent aptasensor for specific and ultrasensitive monitoring ochratoxin A(OTA) was developed using the specific aptamer of OTA(OSA) as recognition dement, an aggregation-induced emission(AIE) molecule(a 9,10-distyrylanthracene with two ammonium groups, DSAI) as a fluorescent probe, and graphene oxide(GO) as a quencher. In the absence of OTA, the AIE probe DSAI and OSA complex(DSAI/OSA) is adsorbed on the GO surface, and the fluorescence of DSAI will be quenched efficiently via the fluorescence resonance energy transfer(FRET) from DSAI to GO. Upon the OTA addition, a more stable complex(OSA-OTA) is formed and released from GO. Meanwhile, DSAI and OSA-OTA can form a new complex(DSAI/OSA-OTA), then the fluorescent signal of DSAI recovers gradually. Therefore, by introducing GO and DSAI, the fluorescence signal of DSAI can be easily turned from "off" to "on" after the addition of OTA, and the ultrasensitive detection of OTA by monitoring the change of the fluorescence signal of DSAI can be readily realized. The detection limit of the assay can reach 0.324 nmol/L with a linear detection range of 10-200 nmol/L. And the aptasensor exhibits high selectivity for OTA against other analogues. Moreover, it has been successfully applied for the detection of OTA in red wine samples. A label-free fluorescent aptasensor for specific and ultrasensitive monitoring ochratoxin A(OTA) was developed using the specific aptamer of OTA(OSA) as recognition dement, an aggregation-induced emission(AIE) molecule(a 9,10-distyrylanthracene with two ammonium groups, DSAI) as a fluorescent probe, and graphene oxide(GO) as a quencher. In the absence of OTA, the AIE probe DSAI and OSA complex(DSAI/OSA) is adsorbed on the GO surface, and the fluorescence of DSAI will be quenched efficiently via the fluorescence resonance energy transfer(FRET) from DSAI to GO. Upon the OTA addition, a more stable complex(OSA-OTA) is formed and released from GO. Meanwhile, DSAI and OSA-OTA can form a new complex(DSAI/OSA-OTA), then the fluorescent signal of DSAI recovers gradually. Therefore, by introducing GO and DSAI, the fluorescence signal of DSAI can be easily turned from "off" to "on" after the addition of OTA, and the ultrasensitive detection of OTA by monitoring the change of the fluorescence signal of DSAI can be readily realized. The detection limit of the assay can reach 0.324 nmol/L with a linear detection range of 10-200 nmol/L. And the aptasensor exhibits high selectivity for OTA against other analogues. Moreover, it has been successfully applied for the detection of OTA in red wine samples.
出处 《Chemical Research in Chinese Universities》 SCIE CAS CSCD 2018年第3期363-368,共6页 高等学校化学研究(英文版)
关键词 LABEL-FREE APTASENSOR Aggregation-induced emission(AIE)-active probe Graphene oxide Ochratoxin A Label-free Aptasensor Aggregation-induced emission(AIE)-active probe Graphene oxide Ochratoxin A
  • 相关文献

同被引文献34

引证文献6

二级引证文献11

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部