摘要 建立了超低温冷冻除脂-气相色谱串联质谱(GC-MS/MS)检测食用植物油中21种邻苯二甲酸酯(PAEs)的新方法。样品用乙腈提取,经超低温(-80℃)冷冻10 min除脂,再经减压浓缩,以正己烷复溶,采用GC-MS/MS多反应监测模式进行测定。结果表明,在考察浓度范围(1~1000 ng/m L)内21种PAEs均呈现良好线性,相关系数均大于0.999,检出限为0.10~8.52μg/kg,定量限为0.32~28.40μg/kg,加标回收率为74.31%~116.62%,相对标准偏差为1.21%~17.82%。对市售7类19个油样的抽样检测,显示邻苯二甲酸二甲酯(DMP)、邻苯二甲酸二乙酯(DEP)、邻苯二甲酸二异丁酯(DIBP)、邻苯二甲酸二丁酯(DBP)、邻苯二甲酸丁基苄基酯(BBP)、邻苯二甲酸(2-丁氧基)乙酯(DBEP)、邻苯二甲酸二正庚酯(DHP)、邻苯二甲酸二(2-乙基己)酯(DEHP)和邻苯二甲酸二正辛酯(DNOP)共9种PAEs被检出,其中DMP、DBP、DBEP、DHP和DEHP检出率均大于90%,含量范围为105.57~2156.76μg/kg。该方法操作简便,成本低,可用于食用植物油中PAEs的有效测定。 A new method was developed for the determination of 21 Phthalic Acid Esters( PAEs) in edible vegetable oils by gas chromatography tandem mass spectrometry( GC-MS/MS) with removing fat through ultra low temperature freezing. With acetonitrile as extractant,sample was extracted and frozen with ultra low temperature at-80 ℃ for 10 min to remove fat,and then the sample solution was evaporated to near dryness by rotary evaporator and redissolved by n-hexane,and then detected by GC-MS/MS under multiple reaction monitoring modes.All analytes had good linearity with correlation coefficient over 0.999 in the investigated range( 1 ~ 1000 ng/m L),the limits of detection( LOD) were 0.10 ~ 8.52 μg/kg,the limits of quantitation( LOQ) were 0.32~28.40 μg/kg,the recoveries were 74.31% ~116.62% with the relative standard deviation ranged of 1.21% ~17.82%.Seven categories of 19 kinds of vegetable oil were examined,the results indicated that dimethyl phthalate( DMP),diethyl phthalate( DEP),diisobutylphthalate( DIBP),di-n-butyl phthalate( DBP),butyl benzyl phthalate( BBP),bis( 2-butoxyethyl) phthalate( DBEP),di-n-heptyl phthalate( DHP),bis( 2-ethylhexyl) phthalate( DEHP) and di-n-octyl phthalate( DNOP) total of 9 PAEs were detected,including DMP,DBP,DBEP,DHP and DEHP detection rate of more than90% with the content in the range of 105.57 ~ 2156.76 μg/kg. The method was easy to operate and low cost,which could be used for the effective determination of PAEs in edible vegetable oil.
作者 马蒙蒙 王宗义 贾明宏 王国庆 盛晔琪 翟孟婷 郑宇 MA Meng-meng;WANG Zong-yi;JIA Ming-hong;WANG Guo- qing;SHENG Ye- qi;ZHAI Meng-ting;ZHENG Yu(Beijing Laboratory of Food Quality and Safety, Beijing Key Laboratory of Agricultural Product Detection and Control for Spoilage Organisms and Pesticides, College of Food Sciences and Engineering,Beijing University of Agricuhure,Beijing 102206,China)
机构地区 北京农学院
出处 《食品工业科技》 CAS CSCD 北大核心 2018年第12期271-274,300,共5页 Science and Technology of Food Industry
基金 北京市教委项目(PXM2017-014207-000038) 北京农学院实验技术体系基金项目(1086716287)
关键词 气相色谱串联质谱 邻苯二甲酸酯 超低温冷冻除脂 食用植物油 gas chromatography-tandem mass spectrometry phthalic acid esters removing fat through ultra low temperaturefreezing edible vegetable oil
  • 相关文献

参考文献13

二级参考文献165

共引文献271

同被引文献55

引证文献4

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部