摘要
选用溶解热法和TAM AIR热导式等温量热仪测试法对粉煤灰、矿渣粉不同掺量的复合胶凝体系进行了水泥水化热测试试验。试验结果表明,较溶解热法而言,TAM AIR测试法测试精度高、试验误差小,能精确测量水泥基胶凝材料水化放热,适用于复合胶凝体系水化放热测试试验。
The test of cement hydration is carried out on the composite cementitious system with different content of fly ash and slag powder by using the method of dissolution heat and TAM AIR thermal conductivity isothermal calorimeter.The results show that the TAM AIR test method has higher testing accuracy and smaller test error than the dissolution heat method, and can accurately measure the hydration exotherm of cement-based cementitious materials, which is suitable for the hydration exothermic test of composite gelling system.
出处
《混凝土与水泥制品》
北大核心
2018年第6期74-77,共4页
China Concrete and Cement Products
基金
中央公益性科研院所基本科研业务费专项资金(Y416011
Y416018)
江苏省水利科技项目"提升沿海水闸混凝土耐久性成套技术研究"(2015013)
关键词
水化热
粉煤灰
矿渣粉
等温量热
溶解热
Hydration heat
Fly ash
Slag powder
Isothermal calorie
Dissolve heat