期刊文献+

Characteristics of Pattern Visual Evoked Potential in Two Eyes with Varying Visual Acuity in One Eye and Forensic Application 被引量:5

Characteristics of Pattern Visual Evoked Potential in Two Eyes with Varying Visual Acuity in One Eye and Forensic Application
下载PDF
导出
摘要 In this study, we aimed to study the pattern visual evoked potentials (P-VEPs) in two eyes with varying visual acuity in one eye and to provide an objective estimation of visual acuity by comparing P-VEPs in one and two eyes. Thirty subjects were chosen, who had one eye with an acuity of 5.0, 4.85, 4.6, 4.0, or scieropia and obstructed vision and the other eye with an acuity of 5.0, respectively. P-VEPs were detected under the large grating stimuli at 3x4 spatial frequency, moderate grating stimuli (12× 16 spatial frequency) and small grating stimuli (48×64 spatial frequency). Under large grating stimuli, there was no significant difference in P100 peak latency between the groups, nor was there a significant difference between the amplitude of two eyes and the amplitude of one normal-vision eye. Under moderate and small grating stimuli, there was a significant difference in P100 peak latency between the group with both eyes having an acuity of 5.0 and the group with visual acuity below 4.0 in one eye. There was a significant difference in P100 amplitude between the group with visual acuity of 5.0 in both eyes and the group with one normal-vision eye. There was no significant difference in the amplitude of two eyes and the amplitude of one normal-vision eye between any other two groups. In forensic identification, characteristics and variability of P-VEPs in one and two eyes can be used to identify malingering or decline in visual acuity. In this study, we aimed to study the pattern visual evoked potentials (P-VEPs) in two eyes with varying visual acuity in one eye and to provide an objective estimation of visual acuity by comparing P-VEPs in one and two eyes. Thirty subjects were chosen, who had one eye with an acuity of 5.0, 4.85, 4.6, 4.0, or scieropia and obstructed vision and the other eye with an acuity of 5.0, respectively. P-VEPs were detected under the large grating stimuli at 3x4 spatial frequency, moderate grating stimuli (12× 16 spatial frequency) and small grating stimuli (48×64 spatial frequency). Under large grating stimuli, there was no significant difference in P100 peak latency between the groups, nor was there a significant difference between the amplitude of two eyes and the amplitude of one normal-vision eye. Under moderate and small grating stimuli, there was a significant difference in P100 peak latency between the group with both eyes having an acuity of 5.0 and the group with visual acuity below 4.0 in one eye. There was a significant difference in P100 amplitude between the group with visual acuity of 5.0 in both eyes and the group with one normal-vision eye. There was no significant difference in the amplitude of two eyes and the amplitude of one normal-vision eye between any other two groups. In forensic identification, characteristics and variability of P-VEPs in one and two eyes can be used to identify malingering or decline in visual acuity.
出处 《Current Medical Science》 SCIE CAS 2018年第2期342-348,共7页 当代医学科学(英文)
关键词 visual evoked potential decline in visual acuity two eyes FORENSICS visual evoked potential decline in visual acuity two eyes forensics
  • 相关文献

同被引文献28

引证文献5

二级引证文献8

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部