摘要 目的系统研究食品接触用铝箔纸中铝的迁移条件和检测方法。方法结合食品接触用铝箔纸实际接触条件,模拟3种迁移实验条件,采用电感耦合等离子体质谱法进行对铝迁移量检测。结果该方法检出限为0.5μg/L,线性范围宽,加标回收率为87.0%~99.2%,相对标准偏差(relative standard deviation,RSD)在0.4%~5.5%(n=6)。结论建立的方法适合食品接触用材料铝箔在不同迁移条件下的铝迁移量的检测。 Objective To systematically study the food contact aluminum foil aluminum migration conditions and detection methods. Methods Combined the actual contact conditions of aluminum foil paper for food contact, 3 migration conditions were simulated and the aluminum migration was detected by inductively coupled plasma-mass spectrometry. Results The limit of detection of the method was 0.5 μg/L, the linear range was wide, and the recoveries of spiked samples ranged from 87.0% to 99.2% with the relative standard deviations (RSDs) of 0.4%-5.5% (n=6). Conclusion The established method is suitable for the detection of aluminum migration amount of food contact material aluminum foil under different migration conditions.
作者 李林林 许超 慕春玲 王恬 LI Lln-Lin;XU Chao;MU Chun-Ling;WANG Tian(Shandong Institute for Product Quality Inspection, Ji'nan 250101, China;Shandong Province Key Laboratory of Materials Chemistry Security Detection Technology, Ji'nan 250101, China)
出处 《食品安全质量检测学报》 CAS 2018年第11期2817-2820,共4页 Journal of Food Safety and Quality
关键词 食品接触用铝箔 电感耦合等离子体质谱法 铝迁移量 food contact aluminum foil aluminum inductively coupled plasma-mass spectrometry aluminummigration
  • 相关文献

参考文献6

二级参考文献34

共引文献47

同被引文献27

引证文献1

二级引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部