摘要 During August 1953 three strong earthquakes of magnitude ranging from 6.3 to 7.2 shook the Ionian Island of Cephalonia (Kefalonia), Greece, and destroyed almost the entire building stock of the Island which consisted primarily of traditional unreinforced masonry (URM) houses. The authorities went on to restructuring of the building stock, using a structural system that is most like what is known today as confined masonry. They designed about 14 types of one- to two-storey buildings providing the engineers with detailed construction plans. These buildings are known as "Arogi" buildings (Arogi in Greek meaning Aid). On the 24th of January and 3rd of February 2014, two earthquakes of magnitude 6.1 and 6.0 struck the island, causing significant soil damages, developing excessively high ground accelerations. Surprisingly, no damage was reported in the "Arogi" buildings. The seismic behavior of the buildings is examined by FEM linear analysis and it is compared to that of URM structures. Computed results illustrate that the displacements of identical URM buildings would be about twice the magnitudes observed in the corresponding "Arogi" ones, with the implication that the earthquake sequence of 2014 would have caused critical damage should the type of structure be of the URM type. Furthermore, it is illustrated that this low cost alternative method of construction is a very effective means of producing earthquake resilient structures, whereas further reduction of seismic displacement may be achieved in the order of 50% with commensurate effects on damage potential, when reinforced slabs are used to replace the timber roofs. During August 1953 three strong earthquakes of magnitude ranging from 6.3 to 7.2 shook the Ionian Island of Cephalonia (Kefalonia), Greece, and destroyed almost the entire building stock of the Island which consisted primarily of traditional unreinforced masonry (URM) houses. The authorities went on to restructuring of the building stock, using a structural system that is most like what is known today as confined masonry. They designed about 14 types of one- to two-storey buildings providing the engineers with detailed construction plans. These buildings are known as "Arogi" buildings (Arogi in Greek meaning Aid). On the 24th of January and 3rd of February 2014, two earthquakes of magnitude 6.1 and 6.0 struck the island, causing significant soil damages, developing excessively high ground accelerations. Surprisingly, no damage was reported in the "Arogi" buildings. The seismic behavior of the buildings is examined by FEM linear analysis and it is compared to that of URM structures. Computed results illustrate that the displacements of identical URM buildings would be about twice the magnitudes observed in the corresponding "Arogi" ones, with the implication that the earthquake sequence of 2014 would have caused critical damage should the type of structure be of the URM type. Furthermore, it is illustrated that this low cost alternative method of construction is a very effective means of producing earthquake resilient structures, whereas further reduction of seismic displacement may be achieved in the order of 50% with commensurate effects on damage potential, when reinforced slabs are used to replace the timber roofs.
出处 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2018年第3期270-290,共21页 结构与土木工程前沿(英文版)
关键词 Cephalonia confined masonry comparative FEM analysis unreinforced masonry seismic damage Cephalonia confined masonry comparative FEM analysis unreinforced masonry seismic damage
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部