期刊文献+

丰满水电站大坝运行状态评价 被引量:6

Operation Condition Assessment of Fengman Hydropower Dam
下载PDF
导出
摘要 丰满水电站是我国第一座大型水电厂,由于建设期的历史原因导致诸多先天性缺陷,加之已达设计使用寿命并超期服役,虽经多次加固补强,但未能从根本上彻底解决问题。通过综合分析坝体混凝土、金属结构等运行现状和洪水复核情况,对丰满大坝运行状态进行评价。 Fengman Hydropower Station is the first large hydropower plant in China.Due to the historical reasons during the construction,the dam owns many congenital defects.In addition with the fact that the dam has reached its design life and is still under operation,the problem could not be solved completely though several reinforcement and strengthening procedures have been applied.In this paper,the operation condition of Fengman Hydropower Dam is evaluated under the comprehensive analysis of the flood check and the operation condition such as the concrete and the metal structure of the dam.
作者 张永鑫 王进 于承跃 李英杰 ZHANG Yongxin;WANG Jin;YU Chengyue;LI Yingjie(Fengman Hydropower Plant, Jilin 132108, China)
机构地区 丰满发电厂
出处 《水电与抽水蓄能》 2018年第3期80-85,共6页 Hydropower and Pumped Storage
关键词 坝体混凝土 金属结构 运行状态 丰满水电站 dam concrete metal structure operation condition Fengman Hydropower Station
  • 相关文献

参考文献5

二级参考文献10

  • 1中国水力发电年鉴(第十二卷)[M].北京:中国电力出版社.2008.
  • 2中国水利水电科学研究院.丰满大坝全面治理方案可行性研究[R].沈阳:东北电网有限公司,2007.
  • 3东北电网有限公司.丰满水电站全面治理工程(建设期)对上下游影响分析报告[R].沈阳:东北电网有限公司,2009.
  • 4中国水电顾问集团华东勘测设计研究院.苦林省丰满水电站大坝全面治理工程预可行性研究报告[R].沈阳:东北电网有限公司.2009.
  • 5中水东北勘测设计研究院有限责任公司.丰满水电站全面治理工程(重建方案)预可行性研究报告[R].沈阳:东北电网有限公司.2009.
  • 6吉林丰满水电站大坝全面治理(重建)工程可行性研究报告[R].2011,12.
  • 7刘青海.丰满大坝第三次定检运行总结报告[R].吉林:丰满发电厂,2011.
  • 8张永鑫.丰满大坝第三次定检现场检查报告[R].吉林:丰满发电厂,2011.
  • 9张铭,范子武.水力不确定性因素对堤防防洪风险效益的影响[J].水利水运工程学报,2011(1):71-75. 被引量:7
  • 10胡朝阳,刘建卫,朱林.糙率改变对城市河道水位及堤防防洪能力的影响[J].水电能源科学,2012,30(10):47-50. 被引量:10