期刊文献+

乙苯装置腐蚀原因分析及解决办法

Analysis and solution of corrosion cause of ethylbenzene unit
下载PDF
导出
摘要 乙苯装置2005年开工以来,因腐蚀多次出现换热器内漏和管线泄漏的情况,为了保证安全生产,2013年大修期间,更换了工艺管线,并对换热器进行材质升级,但效果不佳。换热器升级后出现了腐蚀后移的问题,加重了对管线的腐蚀,在2015年两次发生管线腐蚀泄漏事故,严重影响安全生产,无法坚持3年的大修周期。对乙苯装置腐蚀原因进行了分析并提出解决办法。 Since the start of the ethylbenzene unit in 2005,the leakage and leakage of heat exchanger have occurred many times due to corrosion. For safety production,during the overhaul of 2013,the process pipeline was replaced,and the material of the heat exchanger was upgraded. But the effect is not good. After the upgrading of heat exchangers,the problem of corrosion shifting has increased,which has aggravated the corrosion of pipelines. The two pipeline corrosion and leakage accident happened in 2015,which seriously affected the safety production and could not adhere to the 3 year overhaul cycle. Two research offices leadership organization goes out the corrosion problem,rewarding,and the corrosion inhibitor corrosion problems have a more profound understanding of.
作者 慕金枫 何宏晓 Mu Jinfeng;He Hongxiao(China Petroleum Jinxi Petrochemical Branch Company styrene workshop,Huludao 125001)
出处 《石化技术》 CAS 2018年第5期13-14,6,共3页 Petrochemical Industry Technology
关键词 腐蚀 缓蚀剂 原因分析 corrosion inhibitor reson analysis
  • 相关文献

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部