期刊文献+

燃料组件离线啜吸破损判定准则的优化 被引量:3

The optimization of nuclear assembly offline sipping criterion
下载PDF
导出
摘要 辐照后的核燃料组件若发生破损,则必须采取措施将其甄别出来,以免污染一回路水质,并影响下一循环装料,因此破损组件的检测是一项非常重要的工作,而燃料组件离线啜吸破损判定准则对破损组件的甄别至关重要,本文简述了离线啜吸检测的工作原理,重点阐述了国内核电厂主要的离线啜吸破损判定准则,并对其进行了优化,成功的运用在破损燃料检测工作上。 If the nuclear fuel assemblies leaked after irradiated,we must pick them out by some to prevent contaminating the main loop and affecting the next reloading,so the checking of broken assemblies is an important work,and the nuclear assembly offline sipping criterion is very important to the checking of broken assemblies This article introduced the operating principle of offline sipping, emphases on the main offline sipping criterions in domestic nuclear power plants,and use the criterion after optimization in the checking of broken assemblies successful.
作者 钟波 ZHONG Bo(CNNC Nuclear Power Operations Management Co.,Ltd Core&Fuel Management Department, Jia xing Zhejiang 314000, China)
出处 《科技视界》 2018年第10期191-193,共3页 Science & Technology Vision
关键词 燃料组件 离线啜吸 判定准则 Nuclear fuel assemblies Offline sipping Criterion
  • 相关文献

参考文献1

二级参考文献3

  • 1燃料组件监测与漏损处置管理[Z].浙江海盐:核电秦山联营有限公司技术处,2005.
  • 2Daniel P.PARRAT.破损燃料组件当量直径的判断和解释[Z].1996.
  • 3邓浚献,赵希卷,叶晓丽,赵红,张恩海,高衍刚,刘应林.在线啜吸检测装置的研制[J].核动力工程,1999,20(1):63-66. 被引量:8

共引文献6

同被引文献14

引证文献3

二级引证文献1