期刊文献+

核电厂硼伴热系统管道伴热的设计与计算 被引量:2

Pipeline Heat Tracing Design and Calculation of Nuclear Power Plant Boron Heating System
下载PDF
导出
摘要 文中介绍了核电厂硼伴热系统的设计原理,根据核电厂的工艺要求和实际设备情况,建立了管道热损计算模型,对管道支撑件、阀门等管道附属件的热阱效应进行了折算考量,并应用于某核电厂硼酸再循环泵出口管道电加热装置设计缺陷处理,确保了核电厂系统与设备的稳定运行。系统的实际运行结果表明,所建立的热损计算模型以及基于经验得出管道附属件热阱效应折算考量模型正确可靠,其为硼伴热系统的设计提供了参考。 Introducing design principle of nuclear power plant boron heat tracing,according to process requirements and actual equipment conditions of plant,the pipeline heat loss calculation model is established,heat sink effect of pipeline accessories,such as pipe support,valve,is converted into consideration. And design method and calculation model is successfully applied to the electric heater unit design defect of boron recycle pump outlet pipeline,ensuring the safe and stable operation of system. By actual operation of system,facts have proved that the pipeline heat loss calculation model and empirical calculation model of heat sink effect of pipeline accessories are correct,it provides reference for boron heating system design.
作者 刘刚 LIU Gang(Suzhou Nuclear Power Research Institute Co., Ltd., Suzhou 215004, China)
出处 《管道技术与设备》 CAS 2018年第3期13-15,共3页 Pipeline Technique and Equipment
关键词 核电厂 硼伴热系统 热损计算 热阱效应 计算模型 nuclear power plant boron heating system heat loss calculation heat sink effect calculation model
  • 相关文献

参考文献1

二级参考文献2

  • 1范遂.秦山二期扩建工程硼伴热系统的设计和改进[M].
  • 2张瑞萍;田晖.硼加热系统的设计与研究[M].

共引文献8

同被引文献12

引证文献2

二级引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部