摘要
主要探讨了带式输送电机结构及烧毁的故障表现,并且对带式输送电机烧毁原因展开分析,包括电机超载运转导致烧毁、定子绕组绝缘击穿烧毁、电机自身负荷加重导致烧毁等,通过分析进一步提出了相应的预防措施。
This paper mainly discusses the construction of belt conveyer motor and its failure performance, and analyzes the causes of the burning out of belt conveyer motor, including the burnout of motor caused by overload operation, the breakdown of stator winding insulation, and the breakdown of stator winding, and puts forward related countermeasures.
作者
张勇
Zhang Yong(Xishan Coal and Electricity Group Co., Ltd., Taiyuan Shanxi 03005)
出处
《机械管理开发》
2018年第5期194-195,共2页
Mechanical Management and Development
关键词
煤矿
带式输送机
烧毁
故障分析
coal mine
belt conveyor
burning
fault analysis