摘要
以某站远距离提速道岔表示电压动态变化为例,理论分析目前远距离道岔电缆使用存在的缺陷及风险,同时根据现场应用实际,提出应急处置的措施和解决问题的方法,并对其进行试验验证。
In a case of dynamic changes in the indication voltage of long-distance speed-up turnouts at one station, the defects and risk in the use of cable for long-distance turnout is analyzed theoretically. Meanwhile, corresponding emergency response measures and solution are also provided based on the situation of field application and their validity has also been tested.
出处
《铁道通信信号》
2018年第6期8-10,共3页
Railway Signalling & Communication
关键词
提速道岔
电缆
耦合
分析研究
Speed-up turnouts
Cable
Coupling
Analysis and research