摘要
采用瞬间断电法,得到管/地通电、断电电位曲线,初步判断某管道存在直流杂散电流干扰腐蚀。结合现场调研,确定直流干扰源为地铁2号线。对现场进行开挖验证,进一步断定管道存在地铁直流干扰腐蚀,同时分析了地铁直流干扰的腐蚀原理。
By using instantaneous power method to obtain the pipe/ground potential curve in interval tests, direct current (DC) stray current corrosion was assessed to happen in certain pipe. Combined with field investigation, the DC interference sources were determined to be metro line 2. With the help of excavating and checking, the subway DC interference corrosion was further confirmed. Besides, the subway DC interfer- ence corrosion mechanism was analyzed.
作者
惠海军
杨小雄
秦晓东
李智
HUI Hai-jun;YANG Xiao-xiong;QIN Xiao-dong;LI Zhi(West East Pipeline of Petroehina, Changsha 410022, China)
出处
《材料保护》
CAS
CSCD
北大核心
2018年第6期131-133,共3页
Materials Protection
关键词
直流干扰
腐蚀
判定
direct current interference
corrosion
judgement