期刊文献+

箱型柱-H型钢梁的指形板加强型节点滞回性能研究 被引量:2

RESEARCH ON HYSTERETIC BEHAVIOR OF FINGER-SHAPED PLATE REINFORCED CONNECTION BETWEEN H-TYPE STEEL BEAM AND BOX COLUMN
下载PDF
导出
摘要 指形板加强型节点是对普通盖板连接节点的一种改进形式。为研究指形板连接的滞回性能,利用有限元分析软件ABAQUS建立三维实体单元模型进行循环加载有限元模拟,验证了有限元模型的有效性。设计了11个试件,与普通盖板连接节点对比分析,并研究了指形板厚度、指形深宽比等参数对该节点滞回性能的影响。分析结果表明:指形板加强型节点具有与普通盖板节点相同的承载力和延性,并有效降低了盖板沿宽度方向的应力分布;指形板的厚度对其滞回性能影响很小;指形深宽比的大小应控制在3.0左右。 The finger-shaped plate( FP) reinforced connection is an improved form of the common plate connection. In order to study the hysteretic behavior of the FP connection,the finite element analysis software ABAQUS was used to establish the three-dimensional solid element model to simulate the model under cyclic loading,and the validity of the model was verified. The influence of the parameters such as the thickness of the finger plate and the aspect ratio of the finger on the hysteretic behavior of the joint was studied. The results showed that the FP connection had the same bearing capacity and ductility as the common plate,and the stress distribution in the width direction of the finger plate was reduced effectively. The thickness of the finger plate had little effect on the hysteresis behavior. The size of the finger aspect ratio should be controlled about 3. 0.
作者 张小林 刘辉 ZHANG Xiaolin;LIU Hui(College of Architecture and Civil Engineering, Yangling Vocational & Technical College, Yangling 712100, China;School of Architecture and Civil Engineering, Chang' an University, Xi' an 710061, China)
出处 《钢结构》 2018年第6期39-43,51,共6页 Steel Construction
关键词 梁柱节点 指形板 有限元分析 滞回性能 beam-column connection finger-shaped plate finite element analysis hysteretic behavior
  • 相关文献

参考文献1

二级参考文献14

  • 1AISC (1997), Seismic Provisions for Structural Steel Buildings, Chicago, American Institute of Steel Construction.
  • 2AISC/ANSI (2005a), Seismic Provisions for Structural Steel Buildings, AISC/ANSI 341-05, American Institute of Steel Construction.
  • 3AISC/ANSI (2005b), Commentary on the Specification for Structural Steel Buildings, AISC/ANSI 360-05, American Institute of Steel Construction.
  • 4AISC/ANSI (2009), Prequalified Connections for Special and Intermediate Steel Moment Frames for Seismic Applications, AISC/ANSI 358-05sl-09, American Institute of Steel Construction.
  • 5Chen CC, Lee JM and Lin MC (2003), "Behavior of Steel Moment Connections with a Single Flange Rib," Journal of Engineering Structures, 25(11): 1419-1428.
  • 6Chen CC, Chen SW, Chung MD and Lin MC (2005), "Cyclic Behavior of Unreinforced and Rib Reinforced Moment Connections," Journal of Constructional Steel Research, 61(1): 1-21.
  • 7Chen CC and Lin CC and Lin CH (2006), "Ductile Moment Connections Used in Steel Column Tree Moment Resisting Frames," Journal of Constructional Steel Research, 62(8): 793-801.
  • 8Chou CC and Wu CC (2007), "Performance Evaluation of Steel Reduced Flange Plate Moment Connections," Journal of Earthquake Engineering and Structural Dynamics, 36: 2083-2097.
  • 9FEMA (2000), Recommended Seismic Design Criteria for New Steel Moment-frame Buildings, FEMA 350, Federal Emergency Management Agency.
  • 10Ghobadi MS, Ghassemieh M, Mazroi A and Abolmaali A (2009), "Seismic Performance of Ductile Welded Connections Using T-stiffener," Journal of Constructional Steel Research, 65(4): 766-775.