期刊文献+

Performance of Copper Calorimeter for Heat Transfer Measurement in High Enthalpy Shock Tunnel

Performance of Copper Calorimeter for Heat Transfer Measurement in High Enthalpy Shock Tunnel
原文传递
导出
摘要 Copper calorimeter, based on a calorimetric principle, offers a solution for heat transfer measurement in high enthalpy situation, especially in the erosive flow of high enthalpy shock tunnels. In this study, we numerically investigated the measuring performance of copper calorimeters. Non-ideal effects, such as heat loss to the insulator around and replacement of the average temperature of the copper element by the junction temperature, were discussed in detail. The influences of copper element thickness, copper/constantan wires thickness and sensor diameter were also estimated, with the aim to provide theoretical guidance for the design of copper calorimeter. In addition, corresponding experiments in JF10 high enthalpy shock tunnel were carried out against the data of coaxial thermocouples for verification. Results showed that the non-ideal thermal environment of a copper calorimeter(heat exchange with its surroundings) would result in a smaller measuring heat flux comparing to the one actually loaded; proper thickness of copper element matching the effective test time of shock tunnel was suggested. Besides, preliminary experimental results with corrections showed reasonable agreement with the heat flux of thermocouples, with an average deviation of 8%. Over all, this gauge developed extends and supplements the high enthalpy shock tunnel heat transfer measurements made by other techniques. Copper calorimeter, based on a calorimetric principle, offers a solution for heat transfer measurement in high enthalpy situation, especially in the erosive flow of high enthalpy shock tunnels. In this study, we numerically investigated the measuring performance of copper calorimeters. Non-ideal effects, such as heat loss to the insulator around and replacement of the average temperature of the copper element by the junction temperature, were discussed in detail. The influences of copper element thickness, copper/constantan wires thickness and sensor diameter were also estimated, with the aim to provide theoretical guidance for the design of copper calorimeter. In addition, corresponding experiments in JF10 high enthalpy shock tunnel were carried out against the data of coaxial thermocouples for verification. Results showed that the non-ideal thermal environment of a copper calorimeter(heat exchange with its surroundings) would result in a smaller measuring heat flux comparing to the one actually loaded; proper thickness of copper element matching the effective test time of shock tunnel was suggested. Besides, preliminary experimental results with corrections showed reasonable agreement with the heat flux of thermocouples, with an average deviation of 8%. Over all, this gauge developed extends and supplements the high enthalpy shock tunnel heat transfer measurements made by other techniques.
出处 《Journal of Thermal Science》 SCIE EI CAS CSCD 2018年第4期373-381,共9页 热科学学报(英文版)
基金 financially supported by the National Natural Science Foundation of China(Grant No.11402275,No.11472280 and No.11532014) the China Scholarship Council
关键词 铜元素 热量计 热含量 热转移 隧道 测量 性能 平均温度 copper calorimeter high enthalpy shock tunnel heat transfer hypersonic
  • 相关文献

参考文献7

二级参考文献65

  • 1俞鸿儒,赵伟,袁生学.氢氧爆轰驱动激波风洞的性能[J].气动实验与测量控制,1993,7(3):38-42. 被引量:16
  • 2张若凌,乐嘉陵,王苏,崔季平.强激波阵面的非平衡结构研究[J].实验流体力学,2006,20(2):36-40. 被引量:2
  • 3Alkidas, A.C. (1980), Heat transfer characteristics of a spark ignition engine, J. of Heat Transfer, 102: 189-193.
  • 4Alkidas, A.C. and Cole, R.M. (1985), Transient heat flux measurements in a divided chamber diesel engine, J. of Heat Transfer, 107: 439-444.
  • 5Alkidas, A.C., Puzinauskas, P.V. and Peterson, R.C. (1990), Combustion and heat transfer studies in a sparkignited multi valve optical engine, SAE Trans. J. of Engines, 99: 817-830.
  • 6Gatowski, J.A., Smith, M.K. and Alkidas, A.C. (1989), An experimental investigation of surface thermometry and heat flux, Exper. Therm. Fluid Sci., 2: 280-289.
  • 7Lawton, B. (1987), Effect of compression and expansion on instantaneous heat transfer in reciprocating internal combustion engines, Proc. Instn. Mech. Engrs. Part A, J. of Power and Energy, 201 (A3): 175-186.
  • 8Oude Nijeweme, D. J., Kok, J. B., Stone, C. R., and Wyszynski, L. (2001), Unsteady in-cylinder heat transfer in a spark ignition engine: experiments and modeling, Proc. Instn Mech. Engrs. Part D J. of Automobile Engineering, 215: 747-760.
  • 9Jessen, C., Vetter, M. and Gronig, H. (1993), Experimental studies in the Aachen hypersonic shock tunnel, Z. Flugwiss Weltraumforsch., 17:73-81.
  • 10Gai, S.L. and Joe, W.S. (1992), Laminar heat transfer to blunt cones in high-enthalpy flows, J. Thermophysics Heat Transfer, 6: 433-438.