期刊文献+

超高层建筑自动喷水灭火系统提升可靠性的措施 被引量:5

Measures to improve reliability of automatic sprinkler systems for super high-rise buildings
下载PDF
导出
摘要 为提高超高层建筑中自动喷水灭火系统的可靠性,提出了若干具体的技术措施。明确了提升可靠性措施的完整性和功能性原则,指出了其需要解决的关键问题。从组件可靠性的提高、风险影响的控制、系统加强的措施方面,给出了一些提升可靠性的技术模式和要求,包括环状管网、网状管网、不同报警阀组的喷头交叉布置、不同报警阀组配水管隔层布置、物联网监测等。 In order to improve the reliability of sprinkler systems in super high-rise buildings,several specific technical measures are proposed.The paper has been clarified the improving reliability principle of the integrity and functionality.It points out the key issues that need to be solved.From the aspects of component reliability improvement,risk impact control and system enhancement measures,some technical models and requirements for improving reliability are given.It includes the annular pipe,the network pipe,cross arrangement of sprinkler,cross arrangement of water pipe in the floor,internet of things monitoring and so on.
作者 杨琦 桂佳 朱磊 Yang Qi;Gui Jia;Zhu Lei(East China Architectural Design&Research Institute, Shanghai 200002, China;Shanghai Engineering Research Center of Super High-Rise Building Design, Shanghai 200002, China;Fire Department of Sichuan Province, Chengdu 610036, China)
出处 《给水排水》 CSCD 北大核心 2018年第7期94-97,共4页 Water & Wastewater Engineering
关键词 超高层建筑 自动喷水灭火系统 可靠性 网状管网 喷头交叉布置 配水管隔层布置 物联网监测 Super high-rise building Sprinkler system Reliability Network pipe Cross arrangement of sprinkler Cross arrangement of water pipe in the floor Internet of things monitoring