摘要 在我国炉型多样、煤种多变、长时间低负荷运行现状下,对多台套不同工况下电除尘器性能进行测试,分析对比了炉型、煤种、负荷、烟气温度对低低温电除尘器的影响,评估了长时间运行的稳定性,设计了高压电源的节能措施。测试表明:低低温电除尘器具有较好的炉型、煤种、负荷适应性,在足够比集尘面积的前提下可实现出口烟尘浓度低于10 mg/m^3。 As the complex conditions of different kind boilers,varying coals and low load,LLT-ESPs face more challenges in China. The impact of boiler,coal,load and gas temperature on LLT-ESP was analyzed and its stability was assessed. Then,an energy-saving potential measure for LLT-ESPs was proposed. Test results showed that the outlet dust concentration of LLTESP which has been equipped with enough specific collection area( SCA) could be less than 10 mg/m^3.
作者 赵海宝 何毓忠 章永玮 詹立勇 郭滢 ZHAO Hai-bao;HE Yu-zhong;ZHANG Yong-wei;ZHAN Li-yong;GUO Ying(Zhejiang Feida Environmental Science & Technology Co. , Ltd, Zhuji 311800, China;Zhuji Gengxing Environmental Equipment Co. ,Ltd, Zhuji 311800, China)
出处 《环境工程》 CAS CSCD 北大核心 2018年第6期82-85,共4页 Environmental Engineering
基金 国家重点研发计划"新型高效静电除尘装备"(2017YFB0603202) 高灰煤超低排放技术与装备集成及应用(2016YFC0203704)
关键词 低低温电除尘 超低排放 炉型 低负荷 节能 LLT-ESP ultra-low emission boiler low load energy conservation
  • 相关文献

参考文献4

二级参考文献29

  • 1郦建国,龙辉,郦祝海,等.低低温电除尘技术研究及应用[C]//第十五届中国电除尘学术会议论文集.2013.
  • 2YOSHIO Nakayama,SATOSHI Nakamura,YASUHIRO Takeuchi,et al.MHI high efficiency system-proven technology for mul.
  • 3MASAMI Kato,TADASHI Tanaka,YASUKI Nishimura,et al.Method and system for handling exhaust gas in a boiler:USA.
  • 4土屋喜重,川西好光,大西召一,等.Very cold electrostatic technology of advanced flue gas treatment system for co.
  • 5柳生隆志,土屋喜重,大西召一,等.Recent electrostatic precipitation technology[J].三菱重工技报,1996,33(1):69-73.
  • 6Development and demonstration of waste heat integration with solvent process for more efficient CO2 removal f.
  • 7柴田宪司,三重野光博,山本卓也.電気集麈方法[P].三菱重工技报.2000.
  • 8TOSHIAKI Misaka,YOSHIHIKO Mochizuki.Recent application and running cost of moving electrode type electrostati.
  • 9STEPHENL Francis,ANDREAS Back,PER Johansson.Reduction of rapping losses to improve ESP performance[C]//11th I.
  • 10森雄介,積田佳満,松本有夫,等.Operation results of IHI flue gas desulfurization system-unit No.1 (1 000 MW) of.

共引文献134

同被引文献60

引证文献7

二级引证文献7

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部