摘要 为考察三亚地区民居夏季室内热环境的热舒适状况,选取当地典型传统民居与新建民居各一户作为研究对象,分别测试其室内温度、相对湿度、风速、黑球温度等物理量;以预计适应性平均热感觉指标(APMV)为评价依据进行评价,结果显示旧民居热感觉较新民居略好,夜间较白天略好;并对新旧民居的优劣势进行分析,对当地民居今后的设计提出建议:在外围布置辅助空间与廊道、设通风阁楼、以两层为宜、加强日间自然通风、利用太阳能除湿降温等。 In order to investigate the indoor thermal comfort of residential environment in summer in Sanya,we select typical local traditional houses and the new residential households as the research object. The indoor temperature, relative humidity, wind speed and globe temperature were respectively tested. Based on the predicted adaptive average thermal sensation index(APMV), the results show that the thermal feeling of the old dwelling is slightly better than that of the new one, and the night is slightly better than that of the daytime. Meanwhile, the new and old houses are analyzed to promote their advantages and disadvantages. Some suggestions are put forward for the future design of local houses: arrange the auxiliary space and corridor on the periphery, ventilation attic, taking two floors as appropriate, strengthening daytime natural ventilation, using solar energy to dehumidify and cooling temperature, etc.
作者 刘向梅 刘大龙 刘加平 Liu Xiangmei;Liu Dalong;Liu Jiaping
出处 《建筑与文化》 2018年第7期184-186,共3页 Architecture & Culture
基金 国家自然科学基金重大项目"极端热湿气候区超低能耗建筑模式及科学基础"(项目编号:51590913) 国家自然科学基金项目"城市室内外耦合热环境中的建筑热工设计"(项目编号:51578439)
关键词 崖州合院 民居 室内热环境 现场测试 Yazhou courtyard house: folk house indoor thermal environment field test
  • 相关文献

参考文献2

二级参考文献16

  • 1Kesslling W, Laevemann E, Kapfhammer C. Energy storage for desiccant cooling systems component development[J]. Solar Energy,1998, 64:209--221.
  • 2Lof G O G. Cooling with solar energy[A]. Proc of the World Symposium on Applied Solar Energy[ C], 1955, November 1- 5:171-189.
  • 3Ertas A, Anderson E E, Kiris I. Properties of a new liquid desiccant solution-lithium chloride and calcium-chloride mixture[J]. Solar Energy, 1992, 49(3) : 205--212.
  • 4Kakabaev A, Khandurdyev A. Absorption solar refrigeration unit with open regeneration of solution [J]. Geliotekhnika,1969,5(4) : 28-32.
  • 5中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.绿色建筑评价标准:GB/T50378-2014[S].北京:中国建筑工业出版社,2014.
  • 6中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.公共建筑节能设计标准:GB50189--2005[S].北京:中国建筑工业出版社,2005.
  • 7中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.民用建筑室内热湿环境评价标准:GB/T50785--2012[S].北京:中国建筑工业出版社,2012.
  • 8中华人民共和国住房和城乡建设部,中华人民共和国国家质量监督检验检疫总局.建筑采光设计标准:GB50033-2013[S].北京:中国建筑工业出版社,2012.
  • 9袁炯炯,冉茂宇.土楼民居的室内热环境测试[J].华侨大学学报(自然科学版),2008,29(1):91-93. 被引量:9
  • 10陈晓扬,薛家薇,郑彬.泉州手巾寮民居夏季热环境实测分析[J].建筑学报,2010(S1):84-87. 被引量:16