摘要 目的验证自主研究开发的新型机器人辅助血管腔内介入系统能否有效地完成血管介入治疗及支架植入的复杂操作过程。方法采用石英玻璃模型和成年雌性家猪,分别于体外、体内进行血管介入操作及自膨式支架植入实验,验证该新型机器人血管介入系统应用的有效性。结果体外实验显示,该机器人系统成功完成了远程血管介入操作和支架植入释放操作;体内实验显示,双侧髂动脉支架成形术在机器人辅助下顺利完成,术中及术后未出现夹层、穿孔等手术相关并发症。结论本中心研究开发的机器人血管介入系统可有效地完成远程介入操作及自膨式支架植入释放操作。 Objective To introduce a newly-developed vascular intervention robot, which is independently designed by the authors" center, and to test and verify whether this robot-assisted endovascular interventional system can effectively accomplish the complex operation procedures of vascular interventional therapy and stent implantation. Methods Robot- assisted endovascular interventional system was used to perform both intravascular interventional operation and self-expanding stent implantation in quartz glass model (in vitro) and in adult female domestic pig (in vivo) in order to validate the effectiveness of this novel robot- assisted endovascular interventional system in clinical practice. Results Experiment in vitro showed that this robot-assisted endovaseular interventional system could successfully complete remote vascular interventional operation as well as stent release operation. Experiment in vivo proved that this robot-assisted endovaseular interventional system could smoothly accomplish stenting angioplasty of bilateral iliac arteries. During and after the operation, no procedure- related complications such as arterial dissection or perforation occurred. Conclusion This self-designed robot-assisted endovaseular interventional system can effectively accomplish the remote vascular interventional operation as well as the stent release operation.
作者 陈政 沈毓 陆清声 陈燕青 张昊 谢永富 孙羽东 陈冰 王坤东 景在平 CHEN Zheng;SHEN Yu;LU Qingsheng;CHEN Yanqing;ZHANG Hao;XIE Yongfu;SUN Yudong;CHEN Bing;WANG Kundong;JING Zaiping(Department of Vascular Surgery, Affiliated Changhai Hospital, Second Military Medical University, Shanghai 200433, Chin)
出处 《介入放射学杂志》 CSCD 北大核心 2018年第7期651-654,共4页 Journal of Interventional Radiology
关键词 血管介入 机器人 微创治疗 vascular intervention robot minimally-invasive treatment
  • 相关文献

参考文献4

二级参考文献25

  • 1卢旺盛,刘达,田增民,张大鹏.血管介入手术机器人的关键技术分析[J].生物医学工程研究,2009,28(4):303-306. 被引量:15
  • 2王益红,陈志同.基于PMAC的数控机床手轮功能的实现[J].机械工程师,2005(12):68-70. 被引量:8
  • 3田增民,卢旺盛,赵全军,于新,徐永革,王锐,亓树斌.无框架脑立体定向手术1434例临床分析[J].中华外科杂志,2007,45(10):702-704. 被引量:22
  • 4Ma X, Guo S X, Xiao N, et al. Development of a novel robot-assisted cather system with force feedback [ C]// Proceeding of the 2011 IEEE International Conference on Mechatronics and Automation. Beijing ,2011 : 107 - 111.
  • 5Wang T M, Zhang D P, Liu D. Remote-controlled vascular interventional surgery robot[ J]. The International Journal of Medical Robotics and Computer Assisted Surgery, 2010,2 :194 -201.
  • 6Mack M J. Minimally invasive and robotic surgery [ J ]. Journal of the American Medical Association,2001,285 (5) : 568 - 572.
  • 7Beyar R, Gruberg L, Roguin A, et al. Remote-control percutaneous coronary interventions [ J 1. Journal of American College of Cardiology, 2006,47 ( 2 ) :296 - 300.
  • 8Saliba W, Vivek Y. Atrial fibrillation ablation using a robotic catheter remote control system: initial human experience and long-term follow-up results [ J ]. Journal of the American College of Cardiology, 2008,51 ( 24 ) : 2407 - 241.
  • 9Guo S X, Kondo H, Wang J, et al. A new catheter operating system for medical applications [ C ]//International Conference on Complex Medical Engineering. Beijing: IEEE/ICME, 2007 : 82 - 86.
  • 10Saliba W, Cummings J E, Zhang Y, et al. A novel robotic catheter remote control system [ J 1. Feasibility and Safety of Transseptal Puncture and Endocardial Catheter Navigation, 2006,17(10) :1102 - 1105.

共引文献16

同被引文献29

引证文献5

二级引证文献13

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部