摘要
We found an error in our previous report [Chin. Phys. Lett. 34 (2017) 012902] concerning about the value of voltage on the modulating anode (MA). This mistake occurs when we shifted calculating positive scale to actual negative voltage scale in the DGUN simulation. The value of voltage on the MA is VMA = -33.5 kV as displayed in Table 1. Also Figs. 2(a), 2(b) and 4(a) should be as follows. We note that the error does not affect the conclusion of our report at all, and we apologize for inconvenience of readers brought by our oversight.
We found an error in our previous report [Chin. Phys. Lett. 34 (2017) 012902] concerning about the value of voltage on the modulating anode (MA). This mistake occurs when we shifted calculating positive scale to actual negative voltage scale in the DGUN simulation. The value of voltage on the MA is VMA = -33.5 kV as displayed in Table 1. Also Figs. 2(a), 2(b) and 4(a) should be as follows. We note that the error does not affect the conclusion of our report at all, and we apologize for inconvenience of readers brought by our oversight.
作者
Un-Nisa Zaib
Shigeki Fukuda
Zu-Sheng Zhou
Dong Dong
Sheng-Chang Wang
Ou-Zheng Xiao
Zhi-Jun Lu
Guo-Xi Pei
Un-Nisa Zaib;Shigeki Fukuda;周祖圣;董东;王盛昌;肖欧正;陆志军;裴国玺(Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049;University of Chinese Academy of Sciences,Beijing 100049;Key Laboratory of Particle Acceleration Physics and Technology,Institute of High Energy Physics,Chinese Academy of Sciences,Beijing 100049;High Energy Accelerator Research Organization,KEK,Oho,Ibaraki 305-0801,Japan)