期刊文献+

井下潜油电泵机组变频电压消压器的设计 被引量:1

Design of Variable-frequency Voltage Depressor for Underground Electric Submersible Pump Unit
下载PDF
导出
摘要 潜油电泵在变频驱动时,潜油电机星点处会产生较高的共模电压和高次谐波,严重危害潜油电泵机组井下系统的正常运行。为解决这一问题,设计了一个潜油电泵机组井下变频电压消压器,仿真结果表明:该消压器能有效抑制电动机星点处产生的共模电压与谐波。 Considering that fact that higher common mode voltage and higher harmonics can occur at the star point of submersible motor when submersible pump is driven at variable frequency and this may seriously damage the operation of the downground system of the submersible electric pump unit,a kind of variable-frequency voltage depressor for the underground submersible electric pump unit was designed. Simulation results show that,this voltage depressor designed can effectively suppress the common mode voltage at the star point of the submersible motor and can reduce the negative effects caused by it.
作者 白丽丽 卢晓云 孙文峰 高金兰 杨莉 BAI Li-li;LU Xiao-yun;SUN Wen-feng;GAO Jin-lan;YANG Li(College of Electrical Engineering and Information,Northeast Petroleum University;Pumping Unit Research Institute,Daqing Oilfield Equipment Manufacturing Group Co.)
出处 《化工自动化及仪表》 CAS 2018年第7期550-554,共5页 Control and Instruments in Chemical Industry
基金 "十三五"国家科技重大专项(2016ZX05020-002) 东北石油大学青年基金项目(NEPUQN2014-03)
关键词 变频电压消压器 井下潜油电泵 共模电压 高次谐波 变频器 RC新型网络 谐波抑制 variable-frequency voltage depressor underground electric submersible pump,common mode voltage higher harmonic frequency converter RC new network harmonic supression
  • 相关文献

参考文献3

二级参考文献28

  • 1张宪起.虚拟仪器在自动测试领域中的应用[J].集成电路通讯,2006,24(2):12-17. 被引量:5
  • 2陆海峰,瞿文龙,张星,樊扬,程小猛.抑制共模电压的不对称NZPWM技术[J].清华大学学报(自然科学版),2007,47(7):1122-1125. 被引量:7
  • 3Jouanne V A, Zhang Haoran. An evaluation of mitigation techniques for bearing currents, EMI and over-voltages in ASD applications[J]. IEEE Trans on Industry Applications, 1998, 34(5): 1113-1121.
  • 4Link P. Minimizing electric bearing currents in ASD systems[J]. IEEE Industry Applications Magazine, 1999, 5(4): 55-65.
  • 5MA Da-ming, WU Bin, Zargarl N R, et al. CSI based drive having Feed forward control of inverter input voltage[P]. US: 6269010, 2001- 07- 31.
  • 6Akagi H, Tamura S. A passive EMI filter for eliminating both bearing current and ground leakage current from an inverter driven motor[C]//IEEE 36th Power Electronics Specialists Conference, 2005, Recife: 2442-2450.
  • 7Kanchanrs, Tekwanipn, Baijumr. Three level inverter configuration with common mode voltage elimination forinduction motor drive[C]//lEE Proceedings of Electric Power Applications, 2005, 152(2): 261-270.
  • 8Julian A L, Oriti G Lipo T A. Elimination of common-mode voltage in three phase sinusoidal power converters[J]. IEEE Trans on Power Electronics, 2006, 14(5): 982-989.
  • 9Jauanne V A, Zhang Haoran. A dual-bridge inverter approach to eliminating common-mode voltage and bearing and leakage currents[J]. IEEE Trans on Power Electronics, 1997, 14(1): 43-48.
  • 10Un E, Hava A M. Performance characteristics of the reduced common-mode voltage near state PWM method[C]//Proc EPE, 2007: 1-10.

共引文献27

同被引文献2

引证文献1

二级引证文献2