摘要
通过对某原煤堆放钢结构车间的检测,指出该钢结构车间结构构造不满足规范要求,通过验算发现该车间结构和构件存在强度、刚度和稳定性上的不足,并针对本结构的鉴定结果提出了相应的评估和加固建议。
The examination on the existing structure of some coal-stocking workshop showed that the steel structure in this workshop failed to meet the requirements in terms of the deficiencies in the strength,rigidity and stability in the structure as well as steel parts. Thus,the author evaluated the results of examination and offered advice to strengthen the structure.
作者
靳宏飞
Jin Hongfei(Shanxi Taiyuan Water-Work Municipal Engineering Co.,Ltd,Taiyuan 030009,Chin)
出处
《山西建筑》
2018年第18期46-47,共2页
Shanxi Architecture
关键词
钢结构
构造
加固
steel structure
structure
strengthen