摘要
对OIML R50-4CD(2011版)和OIML R50-5CD(2012版)中对新增称重传感器规定不同表述,认为没有原则差别,但2011版的更为合理。并给出规定表示式的计算方法。以及给出对规定是否恰当的意见。
Different expressions are stipulated for new weighing load cell in OIML R50 - 4CD(2011 Edition) and OIML R50-5CD (2012 Edition). There is no principle difference, but the 2011 version is more reasonable. The calculation method of the specifiedexpression is given. And give advice on whether the regulations are appropriate.
出处
《衡器》
2018年第7期21-24,共4页
Weighing Instrument
关键词
皮带秤
相对Y值
相对Z值
belt scale
relative Y value
relative Z value