期刊文献+

600 MW机组锅炉运行氧量偏差大原因分析及解决措施 被引量:1

Analysis and Solution of Large Deviation of Oxygen in 600 MW Unit Boiler
下载PDF
导出
摘要 某电厂600 MW机组锅炉存在尾部烟道运行氧量偏差较大问题,特别是在高负荷工况下,氧量偏差大情况更加严重,造成氧量较低侧CO含量偏高,严重影响机组安全经济运行。针对此问题进行详细分析,并开展燃烧优化调整试验工作,有效解决了该锅炉运行中尾部烟道两侧氧量偏差问题,确保机组安全经济运行。 The oxygen deviation problems exist in one power plant of 600 MW unit boiler. Especially under high load conditions, the oxygen deviation is more serious.Due to low oxygen side CO content on the high side, it seriously affectes the safe and economic operation. the problems are analyzed in detail.The combustion optimization adjustment test work effectively solves the tail flue in the boiler operation on both sides of the oxygen content of the deviation problem.That ensures the safe and economic operation of the unit.
作者 李彦龙 潘晶 王文生 黄友超 刘彬 LI Yanlong;PAN Jing;WANG Wensheng;HUANG Youchao;LIU Bin(Huadian Electric Power Research Institute,Shenyang,Liaoning 110180,China;Electric Power Research Institute of State Grid Liaoning Electric Power Co.,Ltd.,Shenyang,Liaoning 110006,China;Huadian Baiyinhua Jinshan Power Generation Co.,Ltd.,Xilinguole,Inner Mongolia 026200,China)
出处 《东北电力技术》 2018年第6期56-58,共3页 Northeast Electric Power Technology
关键词 锅炉 氧量偏差 燃烧调整试验 power plant oxygen deviation combustion adjustment test