摘要
分析了供热机组与纯凝机组的差异及冷端优化的注意事项。供热机组的冷端优化应按照采暖季和非采暖季分别考虑。采暖季热耗受背压影响非常小,应按照非采暖季的气象条件、冷端配置、机组运行时间等条件确定机组的设计背压。
The difference between heat supply unit and full condensing unit is analyzed. Advice is provided for cold end optimization. Cold end optimization of the heat supply unit shall consider heating season and non-heating seasons repectively. The influence of backpressure on heat consumption during heating season is less, so the designed backpressure shall be determined based on the climate conditions of non-heating seasons, cold end arrangement and running time of the unit.
作者
徐正
张文征
余悦聪
Xu Zheng;Zhang Wenzheng;Xu Yuecong(Hebei Electric Power Design & Research Institute Co.,Ltd.,Shijiazhuang 050031,China;ACRE Coking & Refi'aetory Engineering Consulting Coqporation,MCC,Dalian 116085,China;Hebei Electric Power Engineering Technology- Research Center,Shijiazhuang 050031,China)
出处
《燃料与化工》
2018年第4期51-54,56,共5页
Fuel & Chemical Processes
关键词
热电联产
供热机组
设计背压
Co-generation of heat and power
Heat supply unit
Designed backpressure