摘要
本文分析了体积管检定流量计的原理和检定过程中的干扰因素及其产生的计量误差, 针对存在的问题, 将体积管标准装置升级改造为静态质量法液体流量标准装置, 并分析该套改造装置的优势.
This paper analyzed the principle of the volume tube verification flowmeter, the interference factors and the measurement errors in the verification process. In view of the existing problems, the standard device of the vol- ume tube was upgraded to a static mass flow standard device, and the advantages of the set were analyzed.
作者
杨小燕
YANG Xiaoyan(China Petroleum & Chemical Corpooration Luoyang Company,Luoyang Henan 471000)
出处
《河南科技》
2018年第16期51-52,共2页
Henan Science and Technology
关键词
体积管
检定误差
静态质量法液体流量标准装置
pipe prover
testing error
static state to measure the liquid consumption meter