摘要
根据核电厂反应堆冷却剂泵(主泵)的功能和供电要求,探讨了主泵的供电回路设计。以某核电厂为例,给出了屏蔽电机主泵供电回路的设计方案和控制要求,分析了主泵供电回路保护功能设置。
Based on the functions and power supply requirements of reactor coolant pump(RCP)in nuclear power plant,the design of power supply circuit for the RCP is analyzed.Taking a nuclear power plant as an example,the design scheme and control requirements of the power supply circuit for the RCP of canned motor are given,and the protection function setting of the RCP power supply circuit is analyzed.
作者
陶果
TAO Guo(Shanghai Nuclear Engineering Research and Design Institute Co.,Ltd.,Shanghai 200233,Chin)
出处
《电工技术》
2018年第11期71-73,共3页
Electric Engineering
基金
国家科技重大专项课题"CAP1400关键设备(如主板
爆破阀等)和材料可靠性研究"(编号2017ZX06002006)
关键词
主泵
核电厂
屏蔽电机
供电回路
RCP
nuclear power plant
canned motor
power supply circuit