摘要
介绍了某电厂1000MW机组高温过热器热电偶频繁损坏的现象,对热电偶损坏原因进行分析,并提出了热电偶改进措施,大大减少了热电偶损坏故障率。
The frequent damage phenomenon of the high temperature superheater thermocouple in a 1000 MW unit of a power plant is introduced.The cause of the damage of the thermocouple is analyzed.The improvement measures of the thermocouple are put forward,greatly reducing the failure rate of the high temperature superheater thermocouple.
作者
杨明洲
金晶
YANG Mingzhou;JIN Jing(Guangdong Yudean Jinghai Power Generation Co.,Ltd.,Jieyang 515223,China)
出处
《电工技术》
2018年第9期109-110,共2页
Electric Engineering
关键词
火力发电厂
高温过热器
热电偶
thermal power plant
high temperature superheater
thermocouple