介绍了南化公司3~#硫酸系统2 000 kW风机运行过程中出现腐蚀严重的问题并分析原因,通过增加1台小风机将SO_3引入吸收循环塔,2 000 kW风机得到保护,设备运行情况良好,解决了由于2 000 kW风机腐蚀造成系统停车的问题。
The problem of serious con'osion in the operation introduced and the reasons are analyzed.By adding a small fan to is protected and the operation of the equipment is good, and the fan is solved. of 2 000 kW fan in the 3# sulphuric acid system of Nanhua company is introduce SO3 into the absorption circulation touter, the 2 000 kW fan problem of the system shutdown caused by the con'osion of 2 000 kW
作者
王利
WANG Li(SINOPEC Nanjing Chemical Industry Co.,Ltd.,Nanjing,Jiangsu,210042,China)
出处
《硫酸工业》
CAS
2018年第7期48-50,共3页
Sulphuric Acid Industry
关键词
硫磺制酸
焚硫炉
离心风机
优化运行
sulphur-burning sulphuric acid production
sulphur burning furnace
centrifugal fan
optimal operation