摘要 当雷击直接击于安装在建筑物上的防雷装置时,建筑物引下线附近必须采取防接触电压和跨步电压的措施,否则危及附近的人身及财产安全,甚至造成严重的人身伤亡事故。结合多年防雷检测工作经验,分析了国家标准GB 50057—2010《建筑物防雷设计规范》中建筑物引下线附近防接触电压和跨步电压的措施,对部分条款进行了较深层次的解释,以期为防雷减灾工作者提供参考。 When the lightning strike directly strikes the lightning protection devices installed on the buildings,the measures of preventing the touch voltage and step voltage must be adopted near the downlead. Otherwise,it will jeopardize the personal safety and property safety in the vicinity and even cause the serious personal injuries and deaths.Combining by many years' experiences in the lightning protection testing field,the measures of preventing the touch voltage and the step voltage near the building downlead were analyzed according to the national standard GB 50057—2010,and some provisions were further explained. It can provide references for lightning protection and disaster mitigation personnels.
作者 纪名祥 JI Mingxiang(Shanghai Jianke Technical Assessment of Construction Co.,Ltd.,Shanghai 201108,China)
出处 《现代建筑电气》 2018年第6期6-9,共4页 Modern Architecture Electric
关键词 防雷技术 引下线 接触电压 跨步电压 人体耐受电压 lightning protection technology downlead touch voltage step voltage human bodywithstand voltage
  • 相关文献

参考文献2

二级参考文献10

  • 1齐红星,陈树德,叶红,乔登江.电磁脉冲作用人体的数值模拟和分析[J].强激光与粒子束,2004,16(12):1581-1584. 被引量:2
  • 2张义军,刘欣生,陈明理,王才伟.人工触发闪电电流测量及特征性分析[J].高原气象,1995,14(1):74-79. 被引量:9
  • 3RHGolde 李文恩 李福寿译.雷电[M].北京:电力工业出版社,1983..
  • 4L B Felsen. Transient electromagnetic fields[M]. New York:[s.n.], 1976.
  • 5V A Rakov and A A Dulzon. Calculated electromagnetic fields of lightening return stroke[J]. Tech Electrodinam, 1987, (1): 87-89.
  • 6R Thottappillil, M Uman. Comparison of lightening return-stroke models[J]. J Geophys Res, 1993, 98(D12): 22, 903-914.
  • 7Nucci C A, Uman M A. Lighnting return stroke current models with specified channel-base current: A review and comparison[J]. J Geophys Res, 1990, 95(D12): 20,395-408.
  • 8Chunshan Yang and Bihua Zhou. Calculation method of electromagnetic field very close to lightning[J]. IEEE Trans Electromag. Compat, 2004, 49(1): 133-141.
  • 9张义军,刘欣生.南方人工引雷试验及电流特征[J].中国电机工程学报,1999,19(4):59-62. 被引量:21
  • 10杨春山,周璧华,陈彬.计算地闪回击电流水平电场的混合法[J].微波学报,2003,19(2):81-84. 被引量:6

共引文献6

同被引文献7

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部