摘要
介绍了某室内冲浪馆的暖通空调设计。包括设计参数、除湿设计、空调设计和防排烟设计等内容。详细阐述了冲浪馆暖通空调设计过程与系统的选择,通过设计计算和方案比较,确定采用空调冷却除湿方案;夏季采用全空气空调系统降温;冬季采用低温地面辐射供暖系统与空调送热风相结合的供暖方式。并总结了设计应注意的问题,为类似工程设计提供了一定的参考。
The paper presents the HVAC design of indoor surfing gymnasium, including the design parameters, dehydration design, air conditioning design and smoke prevention and elimination design,etc. By detailed presenting HVAC design process and system selection and comparing design calculations and solutions, the paper is determined the use of air conditioning cooling dehumidification method,direct current full air conditioning system in summer and the combination of low temperature surface radiant heating system and air-conditioning hot air in winter. The problems that should be paid attention in design process are summed up, which provides reference for the similar engineering design.
作者
田刚
李晓东
郭龙
TIAN Gang1, LI Xiaodong2, GUO Long3(1. Heilongjiang Institute of Technology, Harbin 150050, China; 2. Heilongjiang Institute ofConstruction Technology, Harbin 150050, China; 3. Architecture Design and Research Institute of HIT, Harbin 150090, Chin)
出处
《低温建筑技术》
2018年第7期28-30,50,共4页
Low Temperature Architecture Technology
关键词
冲浪馆
冷却除湿
热管热回收
防结露
湿负荷
surfing gymnasium
air cooling and dehumidifying
heat pipe thermal recovery
anti-condensation
moisture load