期刊文献+

通道长度对泡沫硬化剂稳定性影响的实验研究 被引量:1

Experimental study of the influence of channel length on sclerosing foam stability
原文传递
导出
摘要 目的探讨通道长度对制备泡沫硬化剂稳定性的影响。方法采用不同长度的小直径橡皮管水平连接两个注射器,研究通道长度对制备泡沫稳定性的影响。选用5 ml注射器,液气比1∶4,并在室温环境下进行了5组不同长度橡皮管的实验。实验全程摄像,每组设置重复实验4次,对稳定性指标(析水时间、半衰期、泡沫半衰期体积量和析水率曲线)进行对比分析。结果2 cm,4 cm,6 cm,8 cm长橡皮管实验下,泡沫的各个析水率时间从4 s逐步变长至27 s,而10 cm长度橡皮管实验下,泡沫的析水率时间较之8 cm变短,为18 s左右。结论实验中8 cm为最佳通道长度。改变通道长度能够使制备的泡沫硬化剂稳定性显著提高,临床可以考虑使用最佳通道长度的平行连接装置来制备泡沫。 ObjectiveTo understand the influencing factors of foam stability and help reduce the side effects of treatment, and to achieve better therapeutic effect.MethodsIn the experiment, small diameter rubber tubes of different lengths were used to connect two syringes, and two injectors were injected horizontally to obtain foam and study the effect of channel length on the foam stability. 5ml injector was used, and the ratio of liquid to gas was 1 to 4. Meanwhile, 5 groups of rubber tubes with different lengths were carried out at room temperature. A camera recorded the entire process of foam decay. And foam stability indexes which includes drainage time, half-life, foam half-life volume and the drainage rate curve, were analyzed.ResultsIt showed that when 2cm, 4cm, 6cm and 8cm long rubber tubes were tested, the drainage time of the foam gradually increased from 4s to 27s, while the drainage time of the foam under the 10cm length rubber tube was 18s which was shorter than that of 8cm.ConclusionsIt shows that the 8 cm length in the experiment is the optimal channel length. The stability of the foam hardener can be improved remarkably by changing the length of the channel, and the foam can be prepared by using a parallel connection device with the best channel length in clinical application.
作者 祝盼盼 白逃萍 田琳 何新 蒋文涛 Zhu Panpano;Bai Taoping;Tian Lin;He Xin;Jiang Wentao(Provincial Key Laboratory of Biomechanieal Engineering,Sichuan University,Chengdu 610065,China)
出处 《中华血管外科杂志》 2018年第2期104-107,共4页 Chinese Journal of Vascular Surgery
基金 四川省科技厅应用基础研究项目(2016JY0182) 四川大学实验技术立项项目(20171064)
关键词 通道长度 泡沫硬化剂制备方式 泡沫稳定性 静脉疾病 Channel length Sclerosing foam preparation method Foam stability Venous disease
  • 相关文献

参考文献3

二级参考文献42

  • 1卢凯平,蒋劲松,卢惟钦,杨光唯,来集富,吴昊.站立位转平卧位泡沫硬化剂注射治疗下肢浅静脉曲张[J].中国血管外科杂志(电子版),2013,5(2):109-111. 被引量:3
  • 2古大田 朱家骅.动态液膜厚度测试技术的研究[J].化工学报,1988,(3):375-377.
  • 3Ribatskia G , Jacobi A M . Falling-Film Evaporation on Horizontal Tubes-a Critical Review [J]. International Journal of Refrigeration, 2005, 28:635-653.
  • 4Kang H C, Kim M H. the Development of a Flush-Wire Probe and Calibration Method for Measuring Liquid Film thickness [J]. Int. J. Multiphase Flow, 1992, 18(3): 423 437.
  • 5Collier J G, Hewitt G F. Film Thickness Measurement [J]. ASME Paper 64-WA/HT-41, 1964.
  • 6Coney M W E. The Theory and Application of Conductance Probes for the Measurement of Liquid Film Thickness in Two Phase Flow [J]. J. Phys. E: Scient Instrum., 1973, 6(4): 903 -1002.
  • 7Khoshaim B H. The Flow of Rivulet Over L.P. Steam Turbine Guide Blades [D]. Liverpool: The University of Liverpool, 1975.
  • 8Wasden F K, Dukler A E. Insight into the Hydrodynamics of Free Falling Wavy Films [J]. AICHE Journal, 1989, 35(2): 187 -195.
  • 9Lyu T H, Mudawar I. Statistical Investigation of the Relationship Between Interfacial Waviness and Sensible Heat Transfer to a Falling Liquid Film [J]. Int. J. Heat Mass Transfer, 1991, 34(6): 1451-1464.
  • 10Hu X, Jacobi A M. The Intertube Falling Film Part 1- Flow Characteristics, Mode Transitions and Hysteresis [J]. ASME J. Heat Transfer, 118:618-625.