以老挝HONGSA 3×626 MW电站项目性能试验中环路试验为例,将Fluke754EL过程校验仪分别代替压力变送器和热电偶,作为压力信号源和温度信号源输出标准信号来校验IMP数据采集系统,从而说明该仪器在热工仪表现场校验中的应用。
Taking the loop test of HONGSA 3×626 MW power station project in Laos as an example, make Fluke754 EL process calibrator replace the pressure transmitter and the thermocouple respectively, as pressure signal source and temperature signal source, so as to check IMP data acquisition system by output standard signal, thereby illustrate the instrument verification application in the thermal instrumentation on-site.
作者
李玉林
于壮
邢淑艳
LI Yu-lin;YU Zhuang;XING Shu-yan
出处
《电站系统工程》
2018年第4期73-74,共2页
Power System Engineering