摘要
以贵州某大型新建火电厂为例,采用接地与电磁分析软件,分析了火电厂的雷电环境、土壤泄流性能,以及雷电灾害风险,基于此提出降低风险的措施,并指出火电厂雷电灾害防护的重点。
Taking a newly built large thermal power plant as an example,the lightning environment,soil discharge performance of thermal power plants were analyzed based on grounding and electromagnetic analysis software.The measures of reducing the lightning risk was proposed and the key point of lightning disaster protection in thermal power plant was introduced.
作者
刘波
吴安坤
陈春
LIU Bo;WU Ankun;CHEN Chun(Lighting Protection and Disaster Mitigation Center in Guizho)
出处
《电工技术》
2018年第14期46-48,共3页
Electric Engineering
关键词
火电厂
雷电灾害风险
防雷重点
thermal power plants
lightning risk
key point of lightning protection