期刊文献+

应用能位测定法和SF_6示踪技术检测下分层工作面顶板漏风状况 被引量:3

Air Leakage Measurement of Roof under Lower Working Surface by Energy Level and SF_6 Tracer Test
下载PDF
导出
摘要 利用示踪技术对下分层工作面顶板漏风进行了现场检测,研究了顶板漏风状况。通过能位测定研究了顶板存在的可能漏风路径,在此基础上,利用SF6示踪技术确定了顶板漏风状况。研究发现:试验下分层顶板漏风情况,找出了漏风通道,最大漏风点在实际断层附近,并计算出了漏风方向。 On the basis of using the tracer gas to have a filed test on the air leakage in the gob of the lower stratified working face, study the air leakage condition of the roof and the leakage path of the roof by means of energy level test have determined the air leakage condition of the roof by SF6 tracer technique, according to which have found out the situation and passageway of the air leakage in the stratified roof, and calculated the air leakage wind diretion.
作者 邬灿春 秦汝祥 付婷婷 朱玉 WU Can-chun, QIN Ru-xiang, FU Ting-ting, ZHU Yu(School of Mining and Safety Engineering, Anhui University of Science and Technology, Huainan 232001, Chin)
出处 《煤炭技术》 CAS 2018年第8期164-166,共3页 Coal Technology
关键词 示踪气体 SF6 顶板漏风 下分层 断层 tracer gas SF6 roof air leakage under the stratification fault
  • 相关文献

参考文献7

二级参考文献48

共引文献86

同被引文献11

引证文献3

二级引证文献5

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部