期刊文献+

北京地区大型商业综合体夏季热舒适研究 被引量:2

Indoor Thermal Comfort for Large Commercial Complex in Beijing in Summer
下载PDF
导出
摘要 为研究北京地区大型商业综合体夏季室内热舒适情况,选取该地区两栋典型大型商业综合体,进行了客观热环境与主观热感受的调查,并通过数据拟合和回归分析,将实际热感觉与PM V理论模型预测的结果进行了对比。结果表明,夏季室内实际中性温度比预测中性温度高1.3℃,且实际可接受温度范围比预测范围大。总体来说,北京地区大型商业综合体夏季室内人员对热环境的要求比预测结果低,因此可以适当提高室内温度,在满足室内人员热舒适要求的基础上,挖掘其节能潜力。 In order to explore the indoor thermal comfort of the large commercial complex in Beijing,the objective thermal environment and subjective thermal sensation are investigated in two typical large commercial complexes. Through the data fitting and regression analysis,the actual thermal sensation and the prediction results of PMV theoretical model are compared. The results show that the actual neutral temperature is 1. 3 ℃ higher than the predicted neutral temperature in summer,and the actual acceptable temperature range is larger than the predicted range. G enerally,the requirements of thermal environment of the indoor occupants are lower than the predicted one in large commercial complex in Beijing in summer. As a result,the indoor temperature can be raised appropriately to meet the thermal comfort requirements as well as to exploit its energy-saving potential.
作者 党睿 闫紫薇 王立雄 刘魁星 刘刚 DANG Rui;YAN Zi-wei;WANG Li-xiong;LIU Kui-xing;LIU Gang(School of Architecture,Tianjin University,Tianjin Key Laboratory of Building Physical Environment and Ecological Technology,Tianjin 300072,China)
出处 《建筑节能》 CAS 2018年第6期8-11,共4页 BUILDING ENERGY EFFICIENCY
基金 “十三五”国家重点研发计划资助项目“目标和效果导向的绿色建筑设计新方法及工具”(2016YFC0700200) 国家自然科学基金重点项目“寒冷气候区低能耗”(413308)
关键词 大型商业综合体 现场调研 热环境 热舒适 large commercial complex on- site survey thermal environment thermal comfort
  • 相关文献

参考文献1

二级参考文献17

  • 1王昭俊.哈尔滨市住宅环境热舒适测试结果分析[J].建筑热能通风空调,2004,23(3):5-8. 被引量:4
  • 2ISO 7730 Moderate thermal environment-determination of the PMV and PPD indices and specification of the conditions for thermal comfort. Geneva: International Standard Organization. 1984
  • 3ASHRAE Standard 55-1992 Thermal environmental conditions for human occupancy
  • 4de Dear R J, Auliciems A. Validation of the predicted mean vote model of thermal comfort in six Australian field studies. In: ASHRAE Trans. 1985, 91 (2B).452-468
  • 5Schiller G E, Arens E A, Bauman F S, et al. A field study of thermal environment in office buildings. In:ASHRAE Trans. 1988, 94(2). 280- 308
  • 6Schiller G E. A comparison of measured and predicted comfort in office buildings. In: ASHRAE Trans.1990, 96(1). 609-622
  • 7de Dear R J, Fountain M E. Field experiments on occupant comfort and office thermal environments in a hot-humid climate. In: ASHRAE Trans. 1994, 100(2). 457- 475
  • 8Busch J F. Thermal responses to the THAI office environment. In: ASHRAETrans. 1990, 96(1). 859- 872
  • 9Donnini G, Molina J, Martello C, et al. Field study of occupant comfort and office thermal environments in a cold climate. In: ASHRAE Trans. 1996, 102 (2).795 - 802
  • 10Cena K, de Dear R J. Field study of occupant comfort and office thermal environments in a hot, arid climate.In: ASHRAE Trans. 1999, 105(2). 204- 217

共引文献86

同被引文献22

引证文献2

二级引证文献9

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;