MR T2WI信号特征预测HIFU消融治疗子宫腺肌病疗效 被引量:8

Signal characteristics of MR T2WI in prediction of HIFU treatment outcome for adenomyosis
下载PDF
导出
摘要 目的探讨MR T2WI信号特征对HIFU消融治疗子宫腺肌病疗效的预测作用。方法 502例接受HIFU消融治疗的子宫腺肌病患者,根据术前MR T2WI信号特征分为Ⅰ组(以低信号为主,可有少量等信号)和Ⅱ组(以等信号为主,可有少量低信号);每组进一步分为A(无稍高和极高信号)、B(有稍高信号)、C(有极高或极高合并稍高信号)亚组。分析子宫腺肌病T2WI信号特征与超声消融效果和参数的关系。结果Ⅰ组与Ⅱ组病灶体积消融率(NPVR)差异无统计学意义(t=-0.504,P=0.612)。两组中A亚组NPVR均高于B亚组及C亚组(Ⅰ组:LSD-t=2.608、3.677,P=0.009、<0.001;Ⅱ组:LSD-t=3.255、3.778,P=0.001、<0.001),B亚组与C亚组NPVR差异无统计学意义(Ⅰ组:LSD-t=-0.852,P=0.395;Ⅱ组:LSD-t=0.278,P=0.781)。Ⅰ组与Ⅱ组辐照时间、总消融剂量和能效因子(EEF)差异均无统计学意义(辐照时间:t=-1.716,P=0.087;总消融剂量:t=-1.676,P=0.094;EEF:Z=0.044,P=0.965);两组A亚组辐照时间、总消融剂量和EEF均低于B亚组及C亚组(P均<0.05),B亚组与C亚组辐照时间、总消融剂量和EEF差异均无统计学意义(P均>0.05)。结论 MR T2WI信号特征对HIFU消融治疗子宫腺肌病难易程度和消融效果具有重要预测作用。 Objective To investigate the effect of signal characteristics of MR T2 WI for predicting HIFU treatment outcome for adenomyosis.Methods According to signal characteristics of MR T2 WI before HIFU treatment,502 adenomyosis patients were divided into groupⅠ(lesions with most hypointense and/or little isointense)and group Ⅱ(lesions with most isointense and/or little hypointense).Then patients in each group were further subdivided into subgroup A(without slightly and extremely hyperintense foci in the lesions),subgroup B(with slightly hyperintense foci in the lesions)or subgroup C(with extremely and/or slightly hyperintense foci in the lesions).The correlation of signal characteristics of MR T2 WI for adenomyosis on HIFU ablation results and parameters were analyzed.Results There was no statistical difference of non-perfused volume ratio(NPVR)between groupⅠand groupⅡ(t=-0.504,P=0.612).In both group Ⅰ and group Ⅱ,NPVR of subgroup A was higher than that of subgroup B and subgroup C,respectively(group Ⅰ:LSD-t=2.608,3.677,P=0.009,〈0.001;group Ⅱ:LSD-t=3.255,3.778,P=0.001,〈0.001).There was no statistical difference of NPVR between subgroup B and subgroup C(groupⅠ:LSD-t=-0.852,P=0.395;groupⅡ:LSD-t=0.278,P=0.781).There was no statistical difference of sonication time,total ablation energy and energy efficiency factor(EEF)between group Ⅰ and group Ⅱ,respectively(sonication time:t=-1.716,P=0.087;total ablation energy:t=-1.676,P=0.094;EEF:Z=0.044,P=0.965).In both group Ⅰ and group Ⅱ,sonication time,total ablation energy and EEF of subgroup A were lower than those of subgroup B and subgroup C(all P〈 0.05),while no statistical difference was found between subgroup B and subgroup C(all P〉 0.05).Conclusion Signal characteristics of adenomyosis on MR T2 WI can be used as predictors of HIFU treatment outcome for adenomyosis.
作者 刘畅 陈锦云 陈文直 肖智博 杨超 王玲 魏庆 LIU Chang;CHEN Jinyun;CHEN Wenzhi;XIAO Zhibo;YANG Chao;WANG Ling;WEI Qing(College of Biomedical Engineering,Chongqing Medical University,State Key Laboratory of Ultrasound Engineering in Medicine Co founded by Chongqing and the Ministry of Science and Technology,Chongqing Key Laboratory of Biomedical Engineering,Chongqing Collaborative Innovation Center for Minimally-invasive and Noninvasive Medicine,Chongqing 400016,China;HIEU Center for Tumor Therapy;Department of Rodiology,the First Affiliated Hospital of Chongqing Medical University,Chongqing 400042,China)
出处 《中国介入影像与治疗学》 CSCD 北大核心 2018年第6期345-350,共6页 Chinese Journal of Interventional Imaging and Therapy
基金 国家自然科学基金(11604034 11574039) 国家"十二五"科技支撑计划课题项目(2011BAI14B01) 重庆市教育委项目(KJ1702039)
关键词 子宫腺肌病 高强度聚焦超声消融术 磁共振成像 信号特征 Adenomyosis High intensity focused ultrasound ablation Magnetic resonance imaging Signal characteristics
  • 相关文献

参考文献6

二级参考文献74

  • 1徐忠飞,郑建萍,钟吉俊,吴玉林,张燕,胡明华.子宫腺肌症的MRI表现及诊断价值[J].医学影像学杂志,2012,22(2):314-315. 被引量:9
  • 2Sibille A, Prat F, Chapelon JY, et al. Characterization of extracorporeal ablation of normal and tumor-bearing liver tissue by high intensity focused ultrasound. Ultrasound Med Biol, 1993, 19(8) : 803
  • 3Adams JB, Moore RG, Anderson JH, et al. High-intensity focused ultrasound ablation of rabbit kidney tumors. J Endourol, 1996, 10 : 71
  • 4Bihrle R, Foster RS, Sanghvin NT, et al. High intensity focused ultrasound for treatment of benign prostatic hyperplasia: early United States clinical experience. J Urol,1994,151:1271
  • 5Malcolm AL, ter Haar GR. Ablation of tissue volumes using high intensity focused ultrasound. Ultradsound Med Biol,1996,22(5) : 659
  • 6ter Haar GR, Robertson D. Tissue destruction with focused ultrasound in vivo. Eur Urol, 1993,23(suppl 1) : 8
  • 7Wang ZB, Bai J,Li FQ, et al. Study of a “biological focal region”of high-intensity focused ultrasound. Ultrasound Med Biol, 2003, 29(5) : 749
  • 8Yang R, Sanghvi NT, Rescorla FJ,et al. Liver cancer ablation with extracorporeal high-intensity focused ultrasound. Eur Urol, 1993,23 (Suppl. 1) :17
  • 9Chapelon JY, Margonari J, Theillere Y, et al. Effects of high-intensity focused ultrasound on kidney tissue in the rat and the dog. Eur Urol, 1992,22 :147
  • 10Chen L, ter Haar G, Hill CR. Influence of ablated tissue on the formation of high-intensity focused ultrasound lesions.Ultrasound Med Biol, 1997, 23(6) : 921

共引文献110

同被引文献91

引证文献8

二级引证文献19

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部