摘要
文章阐述了传统UPS进行调峰储能应用技术方案,提出了充放电管理装置的功能要求和二次利用电池作为储能单元的技术要求,介绍了调峰管理应注意的问题,传统UPS进行调峰储能应用技术能够提高UPS的供电安全性,延长后备供电时间,降低电力消耗成本,降低运营成本。
This paper expounds the technical scheme of traditional UPS for peak energy storage, puts forward the functional re - quirement of charge and discharge management device and the technical requirements of secondary use of battery as energy storage unit, and introduces the problems that should be paid attention to in peak-shaving management. Traditional UPS peak-shaving energy storage technology can improve the security of UPS power supply, prolong the backup power supply time, reduce the cost of power consumption, and reduce the operating cost.
出处
《科技创新与应用》
2018年第19期171-172,共2页
Technology Innovation and Application
关键词
UPS
调峰储能
应用
UPS
peak-shaving energy storage
application