摘要
列举了城市综合管廊内几种主要的附属设施,结合相关设计规范及管廊特点,分析了相应附属设施的控制要求,根据控制要求对各种附属设施控制的二次原理图进行比较与讨论,并总结了不同二次控制原理方案的优缺点及适用场合。
Several main ancillary facilities were listed for urban utility tunnel. Combining by the related design specifications and utility tunnel characteristics,the control requirements of corresponding ancillary facilities were analyzed. According to the control requirements,the secondary control schematic diagrams of various ancillary facilities were compared and discussed. The advantages and disadvantages,applicable occasions of the different secondary control schemes were summarized.
作者
李高林
LI Gaolin(Group)Co.,Ltd.,Shanghai 200092,China)
出处
《现代建筑电气》
2018年第5期5-10,共6页
Modern Architecture Electric
基金
国家重点研发计划(2017YFC0805007)资助项目
关键词
城市综合管廊
通风机
照明
排水泵
控制要求
二次控制原理
urban utility tunnel
ventilator
lighting
dewatering pump
control requirement
secondary control schematic diagram