摘要
随着电网飞速发展,10 kV环网越来越普遍,核相工作变得更加频繁且重要。在新投10 kV线路时需要在10 kV开关柜内进行核相,然而,在开关柜内核相需要用绝缘棒推开绝缘挡板,此过程需要耗费大量时间及人力,大大降低了工作效率。本文研制的开关柜核相支架,利用开关柜内部特殊构造,根据不同开关柜宽度,设计支架的宽度调节装置,能够满足500 mm-900 mm开关柜的需要,适应性好,代替了人工将绝缘挡板移开的过程,提高了工作效率。
With the rapid development of power grid,10 kv ring network is becoming more common,phasecheck has become more frequent and important.When 10 kv line is in operation,it needs a phase-check in the switchgear,while it needs insulate the baffle with insulating rods during the check,this process takes time and effort.The novel stent of phase-check will be introduced,it takes the place of manual control and saves two people's work.According to the different width of switchgear,we will design the width adjustment device,which meets the requirement of 500 mm to 900 mm.