水闸液压启闭系统的机械、电气部分在维护不到位时容易发生故障,常见的故障有系统温度偏高、压力不足、异响等。本文以黄埔涌水闸为例,从水闸液压启闭系统和液压油的更换维护和检查等方面,探讨了预防液压启闭系统故障、确保液压启闭系统正常运行的方法。可供其他类似工程参考。
Faults can occur easily when sluice hydraulic hoist system’ s machinery and electrical parts are not maintained sufficiently. Common fault phenomena include high system temperature,insufficient pressure,abnormal noise,etc.Huangpuyong Sluice is adopted as an example in the paper for discussing methods of preventing hydraulic hoist system faults and ensuring normal operation of hydraulic hoist system from two perspectives of maintenance check of sluice hydraulic hoist system and maintenance replacement of hydraulic oil. The method can provide reference for other similar projects.
作者
曾颖委
ZENG Yingwei(Guangzhou Heyong Management Center,Guangzhou 510635,China)
出处
《水利建设与管理》
2018年第6期75-77,共3页
Water Conservancy Construction and Management
关键词
液压启闭系统
常见故障
液压启闭系统维护
液压油维护与更换
hydraulic hoist system
common faults
maintenance of hydraulic hoist system
maintenance and replacement of hydraulic oil