摘要 烟气脱硫喷淋塔一般直径大高度低,处理的烟气量很大,气体进入塔内的几何结构一定程度上影响着塔内流场的分布,从而对SO2的有效吸收及运行性能产生至关重要的影响。常规情况下,烟气从单侧进口以自由射流方式进入喷淋塔,在进口处容易形成回流区、死滞区、涡流区。湿法烟气脱硫系统中的喷淋塔进口结构设计为双面对切进口。通过数值模拟和实验测试相结合的方法,研究了双面对切进口对塔内流场分布的影响。结果表明,采用双面对切进口结构,可以使喷淋塔得到近似于活塞流的均匀流场,从而使烟气均匀一致地通过脱硫喷淋塔,提高了脱硫效率。 Geometric structure of wet flue gas desulfurization spray tower with large diameter and low height affect the distribution of the gas flow field to a certain extent,and further effectively influence the absorption of SO_2 because of the large amount of flue gas. Under normal conditions,the flue gas enters the spray tower with the free jet from one side,and the backflow zone,dead zone and vortex zone are easy to form at the inlet. A wet flue gas desulfurization spray tower with double side cut inlet structure is designed. The influence of the double cut imports of gas on the flow field in the tower was investigated by numerical simulation and experimental test. The results show that the uniform flow field of the piston can be obtained by adopting the double side cutting inlet structure,so that the flue gas can be uniformly and evenly passed through the desulfurization spray tower,so as to improve the desulfurization efficiency.
作者 卜奔 乔昭毓 刘付永 原水东 董川 BU Ben;QIAO Zhao-yu;LIU Fu-yong;YUAN;DONG Chuan(Institute of Environmental Science,Shanxi University 1,Taiyuan 030006,China;Aluminium Plant Design Institute Limited Company 2,Hejin 043304,China)
出处 《科学技术与工程》 北大核心 2018年第16期323-328,共6页 Science Technology and Engineering
关键词 烟气脱硫喷淋塔 双面对切进口 塔内流场 数值模拟 实验测试 flue gas desulphurization spray absorber double-sided opposite tangent import tower flow field numerical simulation experimental test
  • 相关文献

参考文献15

二级参考文献103

共引文献321

同被引文献76

引证文献4

二级引证文献6

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部