目的:通过介绍输尿管肾镜的类型、结构及工作原理,分析输尿管镜的常见故障。方法:明确输尿管镜的常见故障,并分析造成常见故障的原因。结果:通过对这些故障进行总结,医工人员可对输尿管肾镜临床使用者进行操作、清洗、灭菌、储存和运输等环节的规范化性指导。结论:通过规范性等操作,以达到延长输尿管肾镜的使用寿命和减少医疗事故的发生的目的。
Objective: To analyze the common faults of ureteroscopy by introducing the type, structure and working principle of ureteral nephroscope. Methods: To clarify the common faults of ureteroscopy and analyze the causes of common faults. Results: By summarizing these failures, the medical workers can provide standardized guidance for the operation, cleaning, sterilization, storage and transportation of ureteral nephroscope. Conclusion: To prolong the service life of ureteral nephroscope and reduce the incidence of medical malpractice.