针对光伏逆变器在高电压穿越期间可能出现过调制问题,本文分析了电网电压暂升期间的高电压穿越技术,通过判断直流电压大小来确定当前系统是否出现过调制,分析了可能出现的两种过调制情况。为了抑制过调制问题,给出了一种抬升直流侧电压的方法,搭建了高电压穿越实验平台进行了实验。实验结果表明,该方法有效抑制了过调制,从而提高了系统的可控裕度和稳定性。
In view of the over modulation problems that may occur during the high voltage crossing of the photovoltaic inverter, the high voltage crossing technology of power grid voltage swell is analyzed. Determine whether the current system is over modulation by judging the size of the DC voltage. Two kinds of possible over modulation conditions are analyzed. In order to suppress the over modulation problem, a method of lifting the DC side voltage is given. A high voltage crossing experiment platform was set up to carry out the experiment. The experimental results show that the method effectively suppress the over modulation and improves the controllability margin and stability of the system.
作者
周成
江宏玲
戴新荣
谢芳
ZHOU Cheng;JIANG Hongling;DAI Xinrong;XIE Fang(Anhui Institute of International Business,Hefei 231131,China;Anhui & Huaihe River Institute of Hydraulic Research,Hefei 230088,China;Collaborative Innovative Center of Industrial Energy-saving and Power Quality Control,Anhui University,Hefei 230601,China)
出处
《安庆师范大学学报(自然科学版)》
2018年第2期56-59,共4页
Journal of Anqing Normal University(Natural Science Edition)
基金
安徽大学博士启动经费(J01001961)
安徽省教育厅自然科学研究重点项目(KJ2017A861)
国家青年自然科学基金项目(51607002)
关键词
电网电压暂升
高电压穿越
过调制抑制
抬升直流电压
grid voltage rise
high voltage ride-through
over modulation suppression
DC voltage uplift