摘要 鸭儿沟水库是大唐彬长电厂的水源地,以抽蓄下游泾河水为主要水源。水库建成后渗漏不断,虽经两次处理,渗漏依然比较严重,影响水库蓄水和电厂供水安全。本文分析了鸭儿沟水库渗漏的原因,提出了处理的思路和措施。 Yaergou Reservoir is the water source of Datang Binchang Power Plant. Pumping and storage of downstream Jinghe River water are regarded as main water source. After the reservoir construction is completed,leakage constantly occurs. Although it has been treated twice,the leakage is still serious,which affects the water storage of the reservoir and the water supply safety of the power plant. Causes of leakage in Yaergou Reservoir are analyzed,and treatment ideas and measures are proposed.
作者 高杰 GAO Jie(Shaanxi Water Resources and River Reservoir Dispatching Management Center,Xi'an 710004,China)
出处 《中国水能及电气化》 2018年第6期9-11,共3页 China Water Power & Electrification
关键词 鸭儿沟水库 渗漏 处理 Yaergou Reservoir leakage treatment