分析了配电线路通道相关雷电参数、地理条件、线路结构、绝缘配合、线路运行经验对配电线路耐雷水平的影响,基于规程法提出了一种评估配网线路耐雷水平的简易方法,以便优化防雷改造措施。
The article analyzed the influence of lightning parameters, geographical conditions, line structure, insulation coordination and line operation experience on the lightning resistance level of power distribution lines. presented a simple method to evaluate the lightning resistance level of the distribution network.