摘要 本文针对开关柜的触点温度预测这一关键问题,以采集到的110k V高压开关柜触点温度数据为基础,运用Mapreduce模型对一个监测点数据进行分析处理,运用多元线性回归方法,建立关于温度的回归模型,以F回归关系的显著性的判定标准,对预测结果进行分析,结果表明多元线性回归中的纵向回归,能够很好的拟合高压开关柜触点的温度,预测误差小,适用于温度的长期预测。 The aim of this paper was to use the Map-reduce model, analyzing and processing a monitoring point data and use multiple linear regression method to establish model about temperature regression, then the prediction results were analyzed with significant regression relationship between the F criteria. The result shows that the multiple linear regression longitudinal regression can well fit High Voltage Switchgear contact temperature with small prediction error, and it is suitable for long-term forecast of temperature.
作者 何兴平 孙成龙 He Xingping;Sun Chenglong(Yunnan power grid co.,LTD zhaotong power supply company,ZhaoTong Yunnan 65700)
出处 《云南电力技术》 2018年第3期118-121,共4页 Yunnan Electric Power
关键词 多元线性回归 高压开关柜 触点温度 温度预测 multiple linear regression high voltage switchgear contact temperature temperature forecast
  • 相关文献

参考文献6

二级参考文献40

  • 1原思聪,刘道华,刘宏兵,王发展.基于模糊预处理的聚类神经网络模型设计[J].西安建筑科技大学学报(自然科学版),2005,37(2):274-277. 被引量:5
  • 2宋杲,崔景春,袁大陆.2004年高压开关设备运行统计分析[J].电力设备,2006,7(2):10-14. 被引量:46
  • 3王翠茹,孙辰军,杨静,冯海迅.改进残差灰色预测模型在负荷预测中的应用[J].电力系统及其自动化学报,2006,18(1):86-89. 被引量:42
  • 4李瑞先.组态王软件在监控系统中的应用[J].电气传动自动化,2006,28(5):49-51. 被引量:39
  • 5乔维德.模糊神经网络在PLC恒压供水控制系统中的应用[J].电气传动自动化,2007,29(2):48-51. 被引量:6
  • 6Du Lin, Jiang lei, Li Fuqi. On-line partial discharge monitoring and diagnostic system for power transformer[J]. Journal of Ts- inghua University(Science and Technology), 2005, 10(5) : 598- 604.
  • 7Li Yanqing, Lu Fangcheng. Study on ultrasonic generation mechanism of partial discharge[C]// 2005 International Sym- posium on Electrical Insulating Materials. Kitakyushu, Japan:[s. n. ], 2005.
  • 8Peter Brown. Non-intrusive partial discharge measurements on high voltage switchgear[C] // Proceedings of the 1996 IEE Col- loquiumon Monitors and Condition Assessment Equipment. London, UK: IEE, 1996.
  • 9Neii Davies, Yuan Tian, Joe Cheung Yin Tang. Non-intrusive partial discharge measurements of MV switehgears[C]// IEEE International Conference on Condition Monitoring and Diagno- sis. Beijing, China: [s. n. ], 2008.
  • 10Salvatore Cclozzi, Maria Sabrina Sarto. Equivalent source method for the evaluation of the electromagnetic field penetra tion inside enclosures[J]. IEEE Transactions on magnetics, 1996, 32(3): 1497-1500.

共引文献84

同被引文献44

引证文献4

二级引证文献12

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部